Mini Samples ELISA Kit for Serum Amyloid A (SAA)
SA-A; SAA1; PIG4; TP53I4; Amyloid protein A; Amyloid fibril protein AA; Serum amyloid A-1 protein
- Product No.MEA885Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range1.56-100ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.61ng/mL.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Download Instruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 588
For more details, please contact local distributors!US$ 840
For more details, please contact local distributors! US$ 3780
For more details, please contact local distributors! US$ 7140
For more details, please contact local distributors! US$ 58800
For more details, please contact local distributors!
Specificity of the Mini Samples ELISA Kit for Serum Amyloid A (SAA)
This assay has high sensitivity and excellent specificity for detection of Mini Samples Serum Amyloid A (SAA).
No significant cross-reactivity or interference between Mini Samples Serum Amyloid A (SAA) and analogues was observed.
Recovery of the Mini Samples ELISA Kit for Serum Amyloid A (SAA)
Matrices listed below were spiked with certain level of recombinant Mini Samples Serum Amyloid A (SAA) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Serum Amyloid A (SAA) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 96-105 | 99 |
EDTA plasma(n=5) | 82-103 | 88 |
heparin plasma(n=5) | 81-89 | 86 |
Precision of the Mini Samples ELISA Kit for Serum Amyloid A (SAA)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Serum Amyloid A (SAA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Serum Amyloid A (SAA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the Mini Samples ELISA Kit for Serum Amyloid A (SAA)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Serum Amyloid A (SAA) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 79-104% | 84-98% | 88-96% | 80-92% |
EDTA plasma(n=5) | 91-103% | 97-105% | 78-92% | 98-105% |
heparin plasma(n=5) | 79-104% | 88-96% | 95-103% | 90-101% |
Stability of the Mini Samples ELISA Kit for Serum Amyloid A (SAA)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the Mini Samples ELISA Kit for Serum Amyloid A (SAA)
1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well. Incubate 1 hour at 37°C;
3. Aspirate and add 25µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 25µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 25µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 20µL Stop Solution. Read at 450nm immediately.
Test principle of the Mini Samples ELISA Kit for Serum Amyloid A (SAA)
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mini Samples Serum Amyloid A (SAA). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Mini Samples Serum Amyloid A (SAA). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mini Samples Serum Amyloid A (SAA), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mini Samples Serum Amyloid A (SAA) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
GIVEAWAYS
INCREMENT SERVICES
Related products
Catalog No. | Organism species: Homo sapiens (Human) | Applications (RESEARCH USE ONLY!) |
APA885Hu01 | Active Serum Amyloid A (SAA) | Cell culture; Activity Assays. |
RPA885Hu01 | Recombinant Serum Amyloid A (SAA) | Positive Control; Immunogen; SDS-PAGE; WB. |
CPA885Hu21 | OVA Conjugated Serum Amyloid A (SAA) | Immunogen; SDS-PAGE; WB. |
PAA885Hu02 | Polyclonal Antibody to Serum Amyloid A (SAA) | WB; IHC; ICC; IP. |
PAA885Hu01 | Polyclonal Antibody to Serum Amyloid A (SAA) | WB; IHC; ICC; IP. |
LAA885Hu81 | FITC-Linked Polyclonal Antibody to Serum Amyloid A (SAA) | WB; IHC; ICC; IF. |
LAA885Hu71 | Biotin-Linked Polyclonal Antibody to Serum Amyloid A (SAA) | WB; IHC; ICC. |
RAA885Hu25 | Recombinant Antibody to Serum Amyloid A (SAA) | WB; IF; ICC; IHC; IP; FCM. |
RAA885Hu21 | Recombinant Antibody to Serum Amyloid A (SAA) | WB; IHC; ICC. |
RAA885Hu22 | Recombinant Antibody to Serum Amyloid A (SAA) | WB; IHC; ICC. |
RAA885Hu23 | Recombinant Antibody to Serum Amyloid A (SAA) | WB; IF; ICC; IHC; IP; FCM. |
MAA885Hu23 | Monoclonal Antibody to Serum Amyloid A (SAA) | WB; IHC |
MAA885Hu24 | Monoclonal Antibody to Serum Amyloid A (SAA) | WB; IHC; ICC; IP. |
MAA885Hu21 | Monoclonal Antibody to Serum Amyloid A (SAA) | WB; IHC; ICC; IP. |
MAA885Hu22 | Monoclonal Antibody to Serum Amyloid A (SAA) | WB,IHC |
LAA885Hu72 | Biotin-Linked Monoclonal Antibody to Serum Amyloid A (SAA) | WB; IHC; ICC. |
SEA885Hu | ELISA Kit for Serum Amyloid A (SAA) | Enzyme-linked immunosorbent assay for Antigen Detection. |
MEA885Hu | Mini Samples ELISA Kit for Serum Amyloid A (SAA) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEA885Hu | ELISA Kit for Serum Amyloid A (SAA) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCA885Hu | CLIA Kit for Serum Amyloid A (SAA) | Chemiluminescent immunoassay for Antigen Detection. |
LMA885Hu | Multiplex Assay Kit for Serum Amyloid A (SAA) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
PSA885Hu01 | Antibody Pair for Serum Amyloid A (SAA) | ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays. |
KSA885Hu11 | ELISA Kit DIY Materials for Serum Amyloid A (SAA) | Main materials for "Do It(ELISA Kit) Yourself" |
KSA885Hu01 | ELISA Kit DIY Materials for Serum Amyloid A (SAA) | Main materials for "Do It (ELISA Kit) Yourself". |