Multiplex Assay Kit for Voltage Dependent Anion Channel Protein 1 (VDAC1) ,etc. by FLIA (Flow Luminescence Immunoassay)

PORIN-31-HL; Porin 31HM; Plasmalemmal porin; Outer mitochondrial membrane protein porin 1; Voltage-dependent anion-selective channel protein 1

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Voltage Dependent Anion Channel Protein 1 (VDAC1) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Voltage Dependent Anion Channel Protein 1 (VDAC1) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Voltage Dependent Anion Channel Protein 1 (VDAC1) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Voltage Dependent Anion Channel Protein 1 (VDAC1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Voltage Dependent Anion Channel Protein 1 (VDAC1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Voltage Dependent Anion Channel Protein 1 (VDAC1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Voltage Dependent Anion Channel Protein 1 (VDAC1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Voltage Dependent Anion Channel Protein 1 (VDAC1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-102 99
EDTA plasma(n=5) 94-101 97
heparin plasma(n=5) 88-98 92
sodium citrate plasma(n=5) 82-97 92

Precision of the Multiplex Assay Kit for Voltage Dependent Anion Channel Protein 1 (VDAC1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Voltage Dependent Anion Channel Protein 1 (VDAC1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Voltage Dependent Anion Channel Protein 1 (VDAC1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Voltage Dependent Anion Channel Protein 1 (VDAC1) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Voltage Dependent Anion Channel Protein 1 (VDAC1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-90% 83-97% 87-97% 95-102%
EDTA plasma(n=5) 85-102% 92-101% 88-103% 96-105%
heparin plasma(n=5) 80-101% 95-104% 87-95% 92-101%
sodium citrate plasma(n=5) 81-99% 95-105% 91-99% 89-99%

Stability of the Multiplex Assay Kit for Voltage Dependent Anion Channel Protein 1 (VDAC1) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Voltage Dependent Anion Channel Protein 1 (VDAC1) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Voltage Dependent Anion Channel Protein 1 (VDAC1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPG901Hu01 Recombinant Voltage Dependent Anion Channel Protein 1 (VDAC1) Positive Control; Immunogen; SDS-PAGE; WB.
PAG901Hu01 Polyclonal Antibody to Voltage Dependent Anion Channel Protein 1 (VDAC1) WB; IHC; ICC; IP.
CAG901Hu01 Anti-Voltage Dependent Anion Channel Protein 1 (VDAC1) Polyclonal Antibody Loading Control of WB.
MAG901Hu21 Monoclonal Antibody to Voltage Dependent Anion Channel Protein 1 (VDAC1) WB; IHC
CAG901Hu22 Anti-Voltage Dependent Anion Channel Protein 1 (VDAC1) Monoclonal Antibody Loading Control of WB.
SEG901Hu ELISA Kit for Voltage Dependent Anion Channel Protein 1 (VDAC1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMG901Hu Multiplex Assay Kit for Voltage Dependent Anion Channel Protein 1 (VDAC1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
PGG901Hu01 Primer Pair for Voltage Dependent Anion Channel Protein 1 (VDAC1) PCR
GUESTBOOK