Multiplex Assay Kit for Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay)

CMT1F; CMT2E; NF-L; NF68; NFL; 68 kDa neurofilament protein; Neurofilament triplet L protein

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 93-102 96
EDTA plasma(n=5) 90-97 94
heparin plasma(n=5) 78-88 83

Precision of the Multiplex Assay Kit for Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 92-103% 80-99% 92-105% 85-99%
EDTA plasma(n=5) 78-103% 94-105% 83-95% 99-105%
heparin plasma(n=5) 94-102% 79-93% 92-102% 81-88%

Stability of the Multiplex Assay Kit for Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPE038Hu03 Recombinant Neurofilament, Light Polypeptide (NEFL) Positive Control; Immunogen; SDS-PAGE; WB.
RPE038Hu02 Recombinant Neurofilament, Light Polypeptide (NEFL) Positive Control; Immunogen; SDS-PAGE; WB.
RPE038Hu01 Recombinant Neurofilament, Light Polypeptide (NEFL) Positive Control; Immunogen; SDS-PAGE; WB.
CPE038Hu21 OVA Conjugated Neurofilament, Light Polypeptide (NEFL) Immunogen; SDS-PAGE; WB.
PAE038Hu08 Polyclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC; ICC; IP.
PAE038Hu02 Polyclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC; ICC; IP.
PAE038Hu01 Polyclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC; ICC; IP.
LAE038Hu71 Biotin-Linked Polyclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC; ICC.
MAE038Hu25 Monoclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC; ICC; IP.
MAE038Hu27 Monoclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC; ICC; IP.
MAE038Hu23 Monoclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC; ICC; IP.
MAE038Hu22 Monoclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC; ICC; IP.
MAE038Hu21 Monoclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC
MAE038Hu24 Monoclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC; ICC; IP.
FAE038Hu08 Anti-Neurofilament, Light Polypeptide (NEFL) Monoclonal Antibody Flow cytometry.
FAE038Hu02 Anti-Neurofilament, Light Polypeptide (NEFL) Monoclonal Antibody Flow cytometry.
FAE038Hu06 Anti-Neurofilament, Light Polypeptide (NEFL) Monoclonal Antibody Flow cytometry.
FAE038Hu04 Anti-Neurofilament, Light Polypeptide (NEFL) Monoclonal Antibody Flow cytometry.
SEE038Hu ELISA Kit for Neurofilament, Light Polypeptide (NEFL) Enzyme-linked immunosorbent assay for Antigen Detection.
HEE038Hu High Sensitive ELISA Kit for Neurofilament, Light Polypeptide (NEFL) Enzyme-linked immunosorbent assay for Antigen Detection.
MEE038Hu Mini Samples ELISA Kit for Neurofilament, Light Polypeptide (NEFL) Enzyme-linked immunosorbent assay for Antigen Detection.
CEE038Hu ELISA Kit for Neurofilament, Light Polypeptide (NEFL) Enzyme-linked immunosorbent assay for Antigen Detection.
SCE038Hu CLIA Kit for Neurofilament, Light Polypeptide (NEFL) Chemiluminescent immunoassay for Antigen Detection.
LME038Hu Multiplex Assay Kit for Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSE038Hu01 ELISA Kit DIY Materials for Neurofilament, Light Polypeptide (NEFL) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK