Multiplex Assay Kit for Cluster Of Differentiation 56 (CD56) ,etc. by FLIA (Flow Luminescence Immunoassay)

CD56; NCAM1; MSK39; N-CAM-1; NCAM; Neural Cell Adhesion Molecule

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Cluster Of Differentiation 56 (CD56) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Cluster Of Differentiation 56 (CD56) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Cluster Of Differentiation 56 (CD56) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Cluster Of Differentiation 56 (CD56) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Cluster Of Differentiation 56 (CD56) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Cluster Of Differentiation 56 (CD56) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Cluster Of Differentiation 56 (CD56) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Cluster Of Differentiation 56 (CD56) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 84-103 89
EDTA plasma(n=5) 83-97 88
heparin plasma(n=5) 97-105 101
sodium citrate plasma(n=5) 97-105 101

Precision of the Multiplex Assay Kit for Cluster Of Differentiation 56 (CD56) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cluster Of Differentiation 56 (CD56) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cluster Of Differentiation 56 (CD56) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Cluster Of Differentiation 56 (CD56) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cluster Of Differentiation 56 (CD56) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-89% 94-103% 79-103% 89-101%
EDTA plasma(n=5) 83-103% 83-101% 86-105% 91-102%
heparin plasma(n=5) 92-104% 87-101% 81-92% 92-99%
sodium citrate plasma(n=5) 94-101% 80-98% 84-98% 85-99%

Stability of the Multiplex Assay Kit for Cluster Of Differentiation 56 (CD56) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Cluster Of Differentiation 56 (CD56) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Cluster Of Differentiation 56 (CD56) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPB225Hu01 Recombinant Cluster Of Differentiation 56 (CD56) Positive Control; Immunogen; SDS-PAGE; WB.
APB225Hu61 Active Cluster Of Differentiation 56 (CD56) Cell culture; Activity Assays.
APB225Hu62 Active Cluster Of Differentiation 56 (CD56) Cell culture; Activity Assays.
EPB225Hu62 Eukaryotic Cluster Of Differentiation 56 (CD56) Positive Control; Immunogen; SDS-PAGE; WB.
EPB225Hu61 Eukaryotic Cluster Of Differentiation 56 (CD56) Positive Control; Immunogen; SDS-PAGE; WB.
PAB225Hu01 Polyclonal Antibody to Cluster Of Differentiation 56 (CD56) WB; IHC; ICC; IP.
MAB225Hu24 Monoclonal Antibody to Cluster Of Differentiation 56 (CD56) WB; IHC; ICC; IP.
MAB225Hu25 Monoclonal Antibody to Cluster Of Differentiation 56 (CD56) WB; IHC; ICC; IP.
MAB225Hu22 Monoclonal Antibody to Cluster Of Differentiation 56 (CD56) WB; IHC; ICC; IP.
MAB225Hu21 Monoclonal Antibody to Cluster Of Differentiation 56 (CD56) WB; IHC; ICC; IP.
MAB225Hu27 Monoclonal Antibody to Cluster Of Differentiation 56 (CD56) WB; IHC; ICC; IP.
MAB225Hu23 Monoclonal Antibody to Cluster Of Differentiation 56 (CD56) WB; IHC; ICC; IP.
MAB225Hu26 Monoclonal Antibody to Cluster Of Differentiation 56 (CD56) WB; IHC; ICC; IP.
RAB225Hu01 Recombinant Antibody to Cluster Of Differentiation 56 (CD56) WB; IF; ICC; IHC; IP; FCM.
RAB225Hu21 Recombinant Antibody to Cluster Of Differentiation 56 (CD56) WB; IF; ICC; IHC; IP; FCM.
FAB225Hu82 FITC-Linked Anti-Cluster Of Differentiation 56 (CD56) Monoclonal Antibody Flow cytometry.
SEB225Hu ELISA Kit for Cluster Of Differentiation 56 (CD56) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB225Hu Multiplex Assay Kit for Cluster Of Differentiation 56 (CD56) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK