High Sensitive ELISA Kit for Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1)

PARK5; PGP9.5; Uch-L1; Neuron cytoplasmic protein 9.5; Ubiquitin thioesterase L1; Ubiquitin carboxyl-terminal hydrolase isozyme L1

  • High Sensitive ELISA Kit for Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) Packages (Simulation)
  • High Sensitive ELISA Kit for Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) Packages (Simulation)
  • High Sensitive ELISA Kit for Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) Results demonstration
  • HEG945Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the High Sensitive ELISA Kit for Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1)

This assay has high sensitivity and excellent specificity for detection of High Sensitive Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1).
No significant cross-reactivity or interference between High Sensitive Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) and analogues was observed.

Precision of the High Sensitive ELISA Kit for Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability of the High Sensitive ELISA Kit for Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the High Sensitive ELISA Kit for Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the High Sensitive ELISA Kit for Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Sensitive Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Sensitive Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Sensitive Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of High Sensitive Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPG945Hu01 Recombinant Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) Positive Control; Immunogen; SDS-PAGE; WB.
PAG945Hu01 Polyclonal Antibody to Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) WB; IHC; ICC; IP.
FAG945Hu01 Anti-Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) Polyclonal Antibody Flow cytometry.
FAG945Hu41 PE-Linked Anti-Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) Polyclonal Antibody Flow cytometry.
FAG945Hu51 APC-Linked Anti-Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) Polyclonal Antibody Flow cytometry.
FAG945Hu81 FITC-Linked Anti-Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) Polyclonal Antibody Flow cytometry.
MAG945Hu21 Monoclonal Antibody to Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) WB; IHC; ICC; IP.
FAG945Hu02 Anti-Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) Monoclonal Antibody Flow cytometry.
FAG945Hu42 PE-Linked Anti-Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) Monoclonal Antibody Flow cytometry.
FAG945Hu52 APC-Linked Anti-Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) Monoclonal Antibody Flow cytometry.
FAG945Hu82 FITC-Linked Anti-Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) Monoclonal Antibody Flow cytometry.
SEG945Hu ELISA Kit for Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) Enzyme-linked immunosorbent assay for Antigen Detection.
HEG945Hu High Sensitive ELISA Kit for Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) Enzyme-linked immunosorbent assay for Antigen Detection.
AEG945Hu ELISA Kit for Anti-Ubiquitin Carboxyl Terminal Hydrolase L1 Antibody (Anti-UCHL1) Enzyme-linked immunosorbent assay for Antibody Detection.
LMG945Hu Multiplex Assay Kit for Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSG945Hu01 ELISA Kit DIY Materials for Ubiquitin Carboxyl Terminal Hydrolase L1 (UCHL1) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK