ELISA Kit for Immunoglobulin G2 (IgG2)
IGHG2; Ig Gamma-2 Chain C Region; Immunoglobulin Heavy Constant Gamma 2; G2m Marker; Immunoglobulin Gm2
- Product No.CEB682Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Test MethodCompetitive Inhibition
- Assay Length2h
- Detection Range1.23-100ug/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.50ug/mL.
- Sample Typeserum, plasma and other biological fluids
- Download Instruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 466
For more details, please contact local distributors!US$ 665
For more details, please contact local distributors! US$ 2993
For more details, please contact local distributors! US$ 5653
For more details, please contact local distributors! US$ 46550
For more details, please contact local distributors!
Specificity of the ELISA Kit for Immunoglobulin G2 (IgG2)
This assay has high sensitivity and excellent specificity for detection of Immunoglobulin G2 (IgG2).
No significant cross-reactivity or interference between Immunoglobulin G2 (IgG2) and analogues was observed.
Recovery of the ELISA Kit for Immunoglobulin G2 (IgG2)
Matrices listed below were spiked with certain level of recombinant Immunoglobulin G2 (IgG2) and the recovery rates were calculated by comparing the measured value to the expected amount of Immunoglobulin G2 (IgG2) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 97-104 | 101 |
EDTA plasma(n=5) | 95-102 | 99 |
heparin plasma(n=5) | 87-104 | 98 |
Precision of the ELISA Kit for Immunoglobulin G2 (IgG2)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Immunoglobulin G2 (IgG2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Immunoglobulin G2 (IgG2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the ELISA Kit for Immunoglobulin G2 (IgG2)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Immunoglobulin G2 (IgG2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 87-101% | 80-98% | 78-97% | 78-97% |
EDTA plasma(n=5) | 97-105% | 80-92% | 93-101% | 83-97% |
heparin plasma(n=5) | 99-105% | 84-104% | 93-102% | 83-91% |
Stability of the ELISA Kit for Immunoglobulin G2 (IgG2)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the ELISA Kit for Immunoglobulin G2 (IgG2)
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
Test principle of the ELISA Kit for Immunoglobulin G2 (IgG2)
This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Immunoglobulin G2 (IgG2) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Immunoglobulin G2 (IgG2) and unlabeled Immunoglobulin G2 (IgG2) (Standards or samples) with the pre-coated antibody specific to Immunoglobulin G2 (IgG2). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Immunoglobulin G2 (IgG2) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Immunoglobulin G2 (IgG2) in the sample.
GIVEAWAYS
INCREMENT SERVICES
Related products
Catalog No. | Organism species: Homo sapiens (Human) | Applications (RESEARCH USE ONLY!) |
NPB682Hu01 | Native Immunoglobulin G2 (IgG2) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPB682Hu01 | Recombinant Immunoglobulin G2 (IgG2) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAB682Hu01 | Polyclonal Antibody to Immunoglobulin G2 (IgG2) | WB; IHC; ICC; IP. |
LAB682Hu71 | Biotin-Linked Polyclonal Antibody to Immunoglobulin G2 (IgG2) | WB; IHC; ICC. |
LAB682Hu81 | FITC-Linked Polyclonal Antibody to Immunoglobulin G2 (IgG2) | WB; IHC; ICC; IF. |
MAB682Hu22 | Monoclonal Antibody to Immunoglobulin G2 (IgG2) | WB; IHC; ICC; IP. |
CEB682Hu | ELISA Kit for Immunoglobulin G2 (IgG2) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB682Hu | Multiplex Assay Kit for Immunoglobulin G2 (IgG2) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSB682Hu11 | ELISA Kit DIY Materials for Immunoglobulin G2 (IgG2) | Main materials for "Do It (ELISA Kit) Yourself". |