ELISA Kit for Endothelin Converting Enzyme 2 (ECE2)
Methyltransferase-like region
- Product No.CEF414Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Test MethodCompetitive Inhibition
- Assay Length2h
- Detection Range123.46-10000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 45.9pg/mL.
- Sample TypeTissue homogenates, cell lysates and other biological fluids.
- Download Instruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 490
For more details, please contact local distributors!US$ 700
For more details, please contact local distributors! US$ 3150
For more details, please contact local distributors! US$ 5950
For more details, please contact local distributors! US$ 49000
For more details, please contact local distributors!
Specificity of the ELISA Kit for Endothelin Converting Enzyme 2 (ECE2)
This assay has high sensitivity and excellent specificity for detection of Endothelin Converting Enzyme 2 (ECE2).
No significant cross-reactivity or interference between Endothelin Converting Enzyme 2 (ECE2) and analogues was observed.
Recovery of the ELISA Kit for Endothelin Converting Enzyme 2 (ECE2)
Matrices listed below were spiked with certain level of recombinant Endothelin Converting Enzyme 2 (ECE2) and the recovery rates were calculated by comparing the measured value to the expected amount of Endothelin Converting Enzyme 2 (ECE2) in samples.
Matrix | Recovery range (%) | Average(%) |
84-103 | 98 |
Precision of the ELISA Kit for Endothelin Converting Enzyme 2 (ECE2)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Endothelin Converting Enzyme 2 (ECE2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Endothelin Converting Enzyme 2 (ECE2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the ELISA Kit for Endothelin Converting Enzyme 2 (ECE2)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Endothelin Converting Enzyme 2 (ECE2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
85-94% | 78-94% | 90-104% | 95-104% |
Stability of the ELISA Kit for Endothelin Converting Enzyme 2 (ECE2)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the ELISA Kit for Endothelin Converting Enzyme 2 (ECE2)
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
Test principle of the ELISA Kit for Endothelin Converting Enzyme 2 (ECE2)
This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Endothelin Converting Enzyme 2 (ECE2) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Endothelin Converting Enzyme 2 (ECE2) and unlabeled Endothelin Converting Enzyme 2 (ECE2) (Standards or samples) with the pre-coated antibody specific to Endothelin Converting Enzyme 2 (ECE2). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Endothelin Converting Enzyme 2 (ECE2) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Endothelin Converting Enzyme 2 (ECE2) in the sample.
GIVEAWAYS
INCREMENT SERVICES
Related products
Catalog No. | Organism species: Homo sapiens (Human) | Applications (RESEARCH USE ONLY!) |
RPF414Hu01 | Recombinant Endothelin Converting Enzyme 2 (ECE2) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAF414Hu01 | Polyclonal Antibody to Endothelin Converting Enzyme 2 (ECE2) | WB; IHC; ICC; IP. |
MAF414Hu21 | Monoclonal Antibody to Endothelin Converting Enzyme 2 (ECE2) | WB; IHC; ICC; IP. |
CEF414Hu | ELISA Kit for Endothelin Converting Enzyme 2 (ECE2) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMF414Hu | Multiplex Assay Kit for Endothelin Converting Enzyme 2 (ECE2) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |