ELISA Kit for Asymmetrical Dimethylarginine (ADMA)

N,N-Dimethylarginine; NG,NG-Dimethylarginine dihydrochloride; Asymmetric Dimethylarginine

  • ELISA Kit for Asymmetrical Dimethylarginine (ADMA) Packages (Simulation)
  • ELISA Kit for Asymmetrical Dimethylarginine (ADMA) Packages (Simulation)
  • ELISA Kit for Asymmetrical Dimethylarginine (ADMA) Results demonstration
  • CEB301Ge.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Asymmetrical Dimethylarginine (ADMA)

This assay has high sensitivity and excellent specificity for detection of Asymmetrical Dimethylarginine (ADMA).
No significant cross-reactivity or interference between Asymmetrical Dimethylarginine (ADMA) and analogues was observed.

Recovery of the ELISA Kit for Asymmetrical Dimethylarginine (ADMA)

Matrices listed below were spiked with certain level of Asymmetrical Dimethylarginine (ADMA) and the recovery rates were calculated by comparing the measured value to the expected amount of Asymmetrical Dimethylarginine (ADMA) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-92 87
EDTA plasma(n=5) 92-101 96
heparin plasma(n=5) 96-103 101

Precision of the ELISA Kit for Asymmetrical Dimethylarginine (ADMA)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Asymmetrical Dimethylarginine (ADMA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Asymmetrical Dimethylarginine (ADMA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Asymmetrical Dimethylarginine (ADMA)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Asymmetrical Dimethylarginine (ADMA) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-101% 85-97% 98-105% 93-101%
EDTA plasma(n=5) 86-96% 84-101% 91-98% 95-102%
heparin plasma(n=5) 85-102% 98-105% 83-92% 90-101%

Stability of the ELISA Kit for Asymmetrical Dimethylarginine (ADMA)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Asymmetrical Dimethylarginine (ADMA)

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.

Test principle of the ELISA Kit for Asymmetrical Dimethylarginine (ADMA)

This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Asymmetrical Dimethylarginine (ADMA) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Asymmetrical Dimethylarginine (ADMA) and unlabeled Asymmetrical Dimethylarginine (ADMA) (Standards or samples) with the pre-coated antibody specific to Asymmetrical Dimethylarginine (ADMA). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Asymmetrical Dimethylarginine (ADMA) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Asymmetrical Dimethylarginine (ADMA) in the sample.

Related products

Catalog No. Organism species: Pan-species (General) Applications (RESEARCH USE ONLY!)
CPB301Ge11 BSA Conjugated Asymmetrical Dimethylarginine (ADMA) Immunogen; SDS-PAGE; WB.
CPB301Ge21 OVA Conjugated Asymmetrical Dimethylarginine (ADMA) Immunogen; SDS-PAGE; WB.
PAB301Ge01 Polyclonal Antibody to Asymmetrical Dimethylarginine (ADMA) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
LAB301Ge71 Biotin-Linked Polyclonal Antibody to Asymmetrical Dimethylarginine (ADMA) WB; IHC; ICC.
CEB301Ge ELISA Kit for Asymmetrical Dimethylarginine (ADMA) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB301Ge Multiplex Assay Kit for Asymmetrical Dimethylarginine (ADMA) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSB301Ge11 ELISA Kit DIY Materials for Asymmetrical Dimethylarginine (ADMA) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK