ELISA Kit for Anti-Elastin Antibody (Anti-ELN)

WBS, WS, SVAS; Tropoelastin; Supravalvular Aortic Stenosis; Williams-Beuren Syndrome

  • ELISA Kit for Anti-Elastin Antibody (Anti-ELN) Packages (Simulation)
  • ELISA Kit for Anti-Elastin Antibody (Anti-ELN) Packages (Simulation)
  • ELISA Kit for Anti-Elastin Antibody (Anti-ELN) Results demonstration
  • AEB337Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Anti-Elastin Antibody (Anti-ELN)

This assay has high sensitivity and excellent specificity for detection of Anti-Elastin Antibody (Anti-ELN).
No significant cross-reactivity or interference between Anti-Elastin Antibody (Anti-ELN) and analogues was observed.

Recovery of the ELISA Kit for Anti-Elastin Antibody (Anti-ELN)

Matrices listed below were spiked with certain level of Anti-Elastin Antibody (Anti-ELN) and the recovery rates were calculated by comparing the measured value to the expected amount of Anti-Elastin Antibody (Anti-ELN) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 91-105 95
EDTA plasma(n=5) 95-105 99
heparin plasma(n=5) 79-102 84

Precision of the ELISA Kit for Anti-Elastin Antibody (Anti-ELN)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Anti-Elastin Antibody (Anti-ELN) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Anti-Elastin Antibody (Anti-ELN) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Anti-Elastin Antibody (Anti-ELN)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Anti-Elastin Antibody (Anti-ELN) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-98% 84-93% 84-98% 90-105%
EDTA plasma(n=5) 93-101% 82-101% 88-101% 95-103%
heparin plasma(n=5) 91-102% 80-89% 96-104% 97-105%

Stability of the ELISA Kit for Anti-Elastin Antibody (Anti-ELN)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Anti-Elastin Antibody (Anti-ELN)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 5 times;
5. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
6. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Anti-Elastin Antibody (Anti-ELN)

The microtiter plate provided in this kit has been pre-coated with an antigen. Standards or samples are then added to the appropriate microtiter plate wells with a Horseradish Peroxidase (HRP)-conjugated secondary antibody. After TMB substrate solution is added, those wells that contain Anti-Elastin Antibody (Anti-ELN) will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Anti-Elastin Antibody (Anti-ELN) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPB337Hu01 Recombinant Elastin (ELN) Positive Control; Immunogen; SDS-PAGE; WB.
EPB337Hu61 Eukaryotic Elastin (ELN) Positive Control; Immunogen; SDS-PAGE; WB.
CPB337Hu21 OVA Conjugated Elastin (ELN) Immunogen; SDS-PAGE; WB.
CPB337Hu31 KLH Conjugated Elastin (ELN) Immunogen; SDS-PAGE; WB.
PAB337Hu01 Polyclonal Antibody to Elastin (ELN) WB; IHC; ICC; IP.
PAB337Hu08 Polyclonal Antibody to Elastin (ELN) WB; IHC; ICC; IP.
LAB337Hu81 FITC-Linked Polyclonal Antibody to Elastin (ELN) WB; IHC; ICC; IF.
LAB337Hu71 Biotin-Linked Polyclonal Antibody to Elastin (ELN) WB; IHC; ICC.
MAB337Hu21 Monoclonal Antibody to Elastin (ELN) WB
MAB337Hu22 Monoclonal Antibody to Elastin (ELN) WB; IHC; ICC; IP.
MAB337Hu29 Monoclonal Antibody to Elastin (ELN) WB; IHC; ICC; IP.
MAB337Hu24 Monoclonal Antibody to Elastin (ELN) WB; IHC; ICC; IP.
MAB337Hu23 Monoclonal Antibody to Elastin (ELN) WB; IHC.
MAB337Hu25 Monoclonal Antibody to Elastin (ELN) WB; IHC; ICC; IP.
MAB337Hu27 Monoclonal Antibody to Elastin (ELN) WB; IHC; ICC; IP.
HEB337Hu High Sensitive ELISA Kit for Elastin (ELN) Enzyme-linked immunosorbent assay for Antigen Detection.
SEB337Hu ELISA Kit for Elastin (ELN) Enzyme-linked immunosorbent assay for Antigen Detection.
AEB337Hu ELISA Kit for Anti-Elastin Antibody (Anti-ELN) Enzyme-linked immunosorbent assay for Antibody Detection.
SCB337Hu CLIA Kit for Elastin (ELN) Chemiluminescent immunoassay for Antigen Detection.
KSB337Hu01 ELISA Kit DIY Materials for Elastin (ELN) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK