Specificity of the ELISA Kit for Anti-Beta-2-Microglobulin Antibody (Anti-b2M)

This assay has high sensitivity and excellent specificity for detection of Anti-Beta-2-Microglobulin Antibody (Anti-b2M).
No significant cross-reactivity or interference between Anti-Beta-2-Microglobulin Antibody (Anti-b2M) and analogues was observed.

Recovery of the ELISA Kit for Anti-Beta-2-Microglobulin Antibody (Anti-b2M)

Matrices listed below were spiked with certain level of Anti-Beta-2-Microglobulin Antibody (Anti-b2M) and the recovery rates were calculated by comparing the measured value to the expected amount of Anti-Beta-2-Microglobulin Antibody (Anti-b2M) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-99 93
EDTA plasma(n=5) 85-102 96
heparin plasma(n=5) 85-98 95

Precision of the ELISA Kit for Anti-Beta-2-Microglobulin Antibody (Anti-b2M)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Anti-Beta-2-Microglobulin Antibody (Anti-b2M) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Anti-Beta-2-Microglobulin Antibody (Anti-b2M) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Anti-Beta-2-Microglobulin Antibody (Anti-b2M)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Anti-Beta-2-Microglobulin Antibody (Anti-b2M) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 89-98% 96-105% 78-93% 97-105%
EDTA plasma(n=5) 88-104% 87-101% 93-102% 95-105%
heparin plasma(n=5) 88-97% 86-101% 92-99% 89-96%

Stability of the ELISA Kit for Anti-Beta-2-Microglobulin Antibody (Anti-b2M)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Anti-Beta-2-Microglobulin Antibody (Anti-b2M)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 5 times;
5. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
6. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Anti-Beta-2-Microglobulin Antibody (Anti-b2M)

The microtiter plate provided in this kit has been pre-coated with an antigen. Standards or samples are then added to the appropriate microtiter plate wells with a Horseradish Peroxidase (HRP)-conjugated secondary antibody. After TMB substrate solution is added, those wells that contain Anti-Beta-2-Microglobulin Antibody (Anti-b2M) will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Anti-Beta-2-Microglobulin Antibody (Anti-b2M) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPA260Hu01 Recombinant Beta-2-Microglobulin (b2M) Positive Control; Immunogen; SDS-PAGE; WB.
EPA260Hu61 Eukaryotic Beta-2-Microglobulin (b2M) Positive Control; Immunogen; SDS-PAGE; WB.
APA260Hu61 Active Beta-2-Microglobulin (b2M) Cell culture; Activity Assays.
PAA260Hu06 Polyclonal Antibody to Beta-2-Microglobulin (b2M) WB; IHC; ICC; IP.
PAA260Hu01 Polyclonal Antibody to Beta-2-Microglobulin (b2M) WB; IHC; ICC; IP.
FAA260Hu01 Anti-Beta-2-Microglobulin (b2M) Polyclonal Antibody Flow cytometry.
LAA260Hu71 Biotin-Linked Polyclonal Antibody to Beta-2-Microglobulin (b2M) WB; IHC; ICC.
LAA260Hu81 FITC-Linked Polyclonal Antibody to Beta-2-Microglobulin (b2M) WB; IHC; ICC; IF.
MAA260Hu25 Monoclonal Antibody to Beta-2-Microglobulin (b2M) WB; IHC; ICC; IP.
MAA260Hu24 Monoclonal Antibody to Beta-2-Microglobulin (b2M) WB; IHC; ICC; IP.
MAA260Hu23 Monoclonal Antibody to Beta-2-Microglobulin (b2M) WB; IHC; ICC; IP.
MAA260Hu22 Monoclonal Antibody to Beta-2-Microglobulin (b2M) WB; IHC; ICC; IP.
MAA260Hu26 Monoclonal Antibody to Beta-2-Microglobulin (b2M) WB; IHC; ICC; IP.
MAA260Hu21 Monoclonal Antibody to Beta-2-Microglobulin (b2M) WB; IHC
FAA260Hu02 Anti-Beta-2-Microglobulin (b2M) Monoclonal Antibody Flow cytometry.
FAA260Hu04 Anti-Beta-2-Microglobulin (b2M) Monoclonal Antibody Flow cytometry.
FAA260Hu08 Anti-Beta-2-Microglobulin (b2M) Monoclonal Antibody FCM
SEA260Hu ELISA Kit for Beta-2-Microglobulin (b2M) Enzyme-linked immunosorbent assay for Antigen Detection.
AEA260Hu ELISA Kit for Anti-Beta-2-Microglobulin Antibody (Anti-b2M) Enzyme-linked immunosorbent assay for Antibody Detection.
SCA260Hu CLIA Kit for Beta-2-Microglobulin (b2M) Chemiluminescent immunoassay for Antigen Detection.
KSA260Hu01 ELISA Kit DIY Materials for Beta-2-Microglobulin (b2M) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK