CLIA Kit for Histamine (HA)

Histamin

  • CLIA Kit for Histamine (HA) Packages (Simulation)
  • CLIA Kit for Histamine (HA) Packages (Simulation)
  • CLIA Kit for Histamine (HA) Results demonstration
  • CCA927Ge.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Histamine (HA)

This assay has high sensitivity and excellent specificity for detection of Histamine (HA).
No significant cross-reactivity or interference between Histamine (HA) and analogues was observed.

Recovery of the CLIA Kit for Histamine (HA)

Matrices listed below were spiked with certain level of Histamine (HA) and the recovery rates were calculated by comparing the measured value to the expected amount of Histamine (HA) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 98-105 101
EDTA plasma(n=5) 83-103 90
heparin plasma(n=5) 86-101 89

Precision of the CLIA Kit for Histamine (HA)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Histamine (HA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Histamine (HA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Histamine (HA)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Histamine (HA) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-96% 80-97% 81-89% 89-104%
EDTA plasma(n=5) 96-103% 82-90% 91-105% 98-105%
heparin plasma(n=5) 78-90% 90-102% 81-90% 88-102%

Stability of the CLIA Kit for Histamine (HA)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Histamine (HA)

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
7. Read RLU value immediately.

Test principle of the CLIA Kit for Histamine (HA)

The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Histamine (HA). A competitive inhibition reaction is launched between biotin labeled Histamine (HA) and unlabeled Histamine (HA) (Standards or samples) with the pre-coated antibody specific to Histamine (HA). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Histamine (HA) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Histamine (HA) level in the sample or standard.

Related products

Catalog No. Organism species: Pan-species (General) Applications (RESEARCH USE ONLY!)
CPA927Ge41 HSA Conjugated Histamine (HA) Immunogen; SDS-PAGE; WB.
CPA927Ge11 BSA Conjugated Histamine (HA) Immunogen; SDS-PAGE; WB.
CPA927Ge21 OVA Conjugated Histamine (HA) Immunogen; SDS-PAGE; WB.
PAA927Ge01 Polyclonal Antibody to Histamine (HA) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
LAA927Ge71 Biotin-Linked Polyclonal Antibody to Histamine (HA) WB; IHC; ICC.
LAA927Ge81 FITC-Linked Polyclonal Antibody to Histamine (HA) WB; IHC; ICC; IF.
MAA927Ge21 Monoclonal Antibody to Histamine (HA) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
CEA927Ge ELISA Kit for Histamine (HA) Enzyme-linked immunosorbent assay for Antigen Detection.
CCA927Ge CLIA Kit for Histamine (HA) Chemiluminescent immunoassay for Antigen Detection.
LMA927Ge Multiplex Assay Kit for Histamine (HA) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA927Ge11 ELISA Kit DIY Materials for Histamine (HA) Main materials for "Do It(ELISA Kit) Yourself"
GUESTBOOK