CLIA Kit for Chorionic Gonadotropin (CG)

hCG; Human Chorionic Gonadotrophin

  • CLIA Kit for Chorionic Gonadotropin (CG) Packages (Simulation)
  • CLIA Kit for Chorionic Gonadotropin (CG) Packages (Simulation)
  • CLIA Kit for Chorionic Gonadotropin (CG) Results demonstration
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Chorionic Gonadotropin (CG)

This assay has high sensitivity and excellent specificity for detection of Chorionic Gonadotropin (CG).
No significant cross-reactivity or interference between Chorionic Gonadotropin (CG) and analogues was observed.

Recovery of the CLIA Kit for Chorionic Gonadotropin (CG)

Matrices listed below were spiked with certain level of recombinant Chorionic Gonadotropin (CG) and the recovery rates were calculated by comparing the measured value to the expected amount of Chorionic Gonadotropin (CG) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 87-96 93
EDTA plasma(n=5) 78-102 83
heparin plasma(n=5) 85-103 95

Precision of the CLIA Kit for Chorionic Gonadotropin (CG)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chorionic Gonadotropin (CG) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chorionic Gonadotropin (CG) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Chorionic Gonadotropin (CG)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Chorionic Gonadotropin (CG) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-101% 89-103% 88-102% 81-103%
EDTA plasma(n=5) 95-105% 78-103% 94-102% 86-101%
heparin plasma(n=5) 78-102% 85-92% 80-94% 88-102%

Stability of the CLIA Kit for Chorionic Gonadotropin (CG)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Chorionic Gonadotropin (CG)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Chorionic Gonadotropin (CG)

The microplate provided in this kit has been pre-coated with an antibody specific to Chorionic Gonadotropin (CG). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Chorionic Gonadotropin (CG). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Chorionic Gonadotropin (CG) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
PAD216Hu01 Polyclonal Antibody to Chorionic Gonadotropin (CG) WB; IHC; ICC; IP.
LAD216Hu71 Biotin-Linked Polyclonal Antibody to Chorionic Gonadotropin (CG) WB; IHC; ICC.
SED216Hu ELISA Kit for Chorionic Gonadotropin (CG) Enzyme-linked immunosorbent assay for Antigen Detection.
SCD216Hu CLIA Kit for Chorionic Gonadotropin (CG) Chemiluminescent immunoassay for Antigen Detection.
LMD216Hu Multiplex Assay Kit for Chorionic Gonadotropin (CG) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK