Mini Samples ELISA Kit for Interleukin 20 (IL20)

IL10D; IL10-D; ZCYTO10; Cytokine Zcyto10

  • Mini Samples ELISA Kit for Interleukin 20 (IL20) Packages (Simulation)
  • Mini Samples ELISA Kit for Interleukin 20 (IL20) Packages (Simulation)
  • Mini Samples ELISA Kit for Interleukin 20 (IL20) Results demonstration
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Mini Samples ELISA Kit for Interleukin 20 (IL20)

This assay has high sensitivity and excellent specificity for detection of Mini Samples Interleukin 20 (IL20).
No significant cross-reactivity or interference between Mini Samples Interleukin 20 (IL20) and analogues was observed.

Recovery of the Mini Samples ELISA Kit for Interleukin 20 (IL20)

Matrices listed below were spiked with certain level of recombinant Mini Samples Interleukin 20 (IL20) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Interleukin 20 (IL20) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 89-104 93
EDTA plasma(n=5) 93-101 97
heparin plasma(n=5) 80-104 89

Precision of the Mini Samples ELISA Kit for Interleukin 20 (IL20)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Interleukin 20 (IL20) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Interleukin 20 (IL20) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Mini Samples ELISA Kit for Interleukin 20 (IL20)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Interleukin 20 (IL20) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-101% 97-104% 80-103% 78-90%
EDTA plasma(n=5) 79-91% 94-105% 82-95% 88-96%
heparin plasma(n=5) 98-105% 89-104% 83-101% 98-105%

Stability of the Mini Samples ELISA Kit for Interleukin 20 (IL20)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Mini Samples ELISA Kit for Interleukin 20 (IL20)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the Mini Samples ELISA Kit for Interleukin 20 (IL20)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mini Samples Interleukin 20 (IL20). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Mini Samples Interleukin 20 (IL20). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mini Samples Interleukin 20 (IL20), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mini Samples Interleukin 20 (IL20) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
EPC058Mu61 Eukaryotic Interleukin 20 (IL20) Positive Control; Immunogen; SDS-PAGE; WB.
RPC058Mu01 Recombinant Interleukin 20 (IL20) Positive Control; Immunogen; SDS-PAGE; WB.
RPC058Mu02 Recombinant Interleukin 20 (IL20) Positive Control; Immunogen; SDS-PAGE; WB.
APC058Mu61 Active Interleukin 20 (IL20) Cell culture; Activity Assays.
PAC058Mu01 Polyclonal Antibody to Interleukin 20 (IL20) WB; IHC; ICC; IP.
PAC058Mu02 Polyclonal Antibody to Interleukin 20 (IL20) WB; IHC; ICC; IP.
SEC058Mu ELISA Kit for Interleukin 20 (IL20) Enzyme-linked immunosorbent assay for Antigen Detection.
MEC058Mu Mini Samples ELISA Kit for Interleukin 20 (IL20) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC058Mu Multiplex Assay Kit for Interleukin 20 (IL20) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK