High Sensitive ELISA Kit for Matrix Metalloproteinase 13 (MMP13)

CLG3; Collagenase 3

  • High Sensitive ELISA Kit for Matrix Metalloproteinase 13 (MMP13) Packages (Simulation)
  • High Sensitive ELISA Kit for Matrix Metalloproteinase 13 (MMP13) Packages (Simulation)
  • High Sensitive ELISA Kit for Matrix Metalloproteinase 13 (MMP13) Results demonstration
  • HEA099Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the High Sensitive ELISA Kit for Matrix Metalloproteinase 13 (MMP13)

This assay has high sensitivity and excellent specificity for detection of High Sensitive Matrix Metalloproteinase 13 (MMP13).
No significant cross-reactivity or interference between High Sensitive Matrix Metalloproteinase 13 (MMP13) and analogues was observed.

Recovery of the High Sensitive ELISA Kit for Matrix Metalloproteinase 13 (MMP13)

Matrices listed below were spiked with certain level of recombinant High Sensitive Matrix Metalloproteinase 13 (MMP13) and the recovery rates were calculated by comparing the measured value to the expected amount of High Sensitive Matrix Metalloproteinase 13 (MMP13) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 86-101 90
heparin plasma(n=5) 78-96 84

Precision of the High Sensitive ELISA Kit for Matrix Metalloproteinase 13 (MMP13)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive Matrix Metalloproteinase 13 (MMP13) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive Matrix Metalloproteinase 13 (MMP13) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the High Sensitive ELISA Kit for Matrix Metalloproteinase 13 (MMP13)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of High Sensitive Matrix Metalloproteinase 13 (MMP13) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 97-105% 79-99% 79-99% 89-96%
heparin plasma(n=5) 78-101% 79-102% 85-103% 98-105%

Stability of the High Sensitive ELISA Kit for Matrix Metalloproteinase 13 (MMP13)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the High Sensitive ELISA Kit for Matrix Metalloproteinase 13 (MMP13)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the High Sensitive ELISA Kit for Matrix Metalloproteinase 13 (MMP13)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Sensitive Matrix Metalloproteinase 13 (MMP13). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Sensitive Matrix Metalloproteinase 13 (MMP13). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Sensitive Matrix Metalloproteinase 13 (MMP13), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of High Sensitive Matrix Metalloproteinase 13 (MMP13) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPA099Mu01 Recombinant Matrix Metalloproteinase 13 (MMP13) Positive Control; Immunogen; SDS-PAGE; WB.
RPA099Mu02 Recombinant Matrix Metalloproteinase 13 (MMP13) Positive Control; Immunogen; SDS-PAGE; WB.
PAA099Mu01 Polyclonal Antibody to Matrix Metalloproteinase 13 (MMP13) WB; IHC; ICC; IP.
PAA099Mu02 Polyclonal Antibody to Matrix Metalloproteinase 13 (MMP13) WB; IHC; ICC; IP.
LAA099Mu71 Biotin-Linked Polyclonal Antibody to Matrix Metalloproteinase 13 (MMP13) WB; IHC; ICC.
SEA099Mu ELISA Kit for Matrix Metalloproteinase 13 (MMP13) Enzyme-linked immunosorbent assay for Antigen Detection.
HEA099Mu High Sensitive ELISA Kit for Matrix Metalloproteinase 13 (MMP13) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA099Mu CLIA Kit for Matrix Metalloproteinase 13 (MMP13) Chemiluminescent immunoassay for Antigen Detection.
LMA099Mu Multiplex Assay Kit for Matrix Metalloproteinase 13 (MMP13) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK