High Sensitive ELISA Kit for Bovine Serum Albumin (BSA)
Bovine Albumin; Fraction V
- Product No.HEA248Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Test MethodCompetitive Inhibition
- Assay Length3h
- Detection Range246.9-20,000ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 87.2ng/mL.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Download Instruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 352
For more details, please contact local distributors!US$ 503
For more details, please contact local distributors! US$ 2264
For more details, please contact local distributors! US$ 4276
For more details, please contact local distributors! US$ 35210
For more details, please contact local distributors!
Specificity of the High Sensitive ELISA Kit for Bovine Serum Albumin (BSA)
This assay has high sensitivity and excellent specificity for detection of High Sensitive Bovine Serum Albumin (BSA).
No significant cross-reactivity or interference between High Sensitive Bovine Serum Albumin (BSA) and analogues was observed.
Recovery of the High Sensitive ELISA Kit for Bovine Serum Albumin (BSA)
Matrices listed below were spiked with certain level of recombinant High Sensitive Bovine Serum Albumin (BSA) and the recovery rates were calculated by comparing the measured value to the expected amount of High Sensitive Bovine Serum Albumin (BSA) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 91-101 | 97 |
EDTA plasma(n=5) | 96-103 | 99 |
heparin plasma(n=5) | 95-103 | 99 |
Precision of the High Sensitive ELISA Kit for Bovine Serum Albumin (BSA)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive Bovine Serum Albumin (BSA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive Bovine Serum Albumin (BSA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the High Sensitive ELISA Kit for Bovine Serum Albumin (BSA)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of High Sensitive Bovine Serum Albumin (BSA) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 79-97% | 79-92% | 81-103% | 94-101% |
EDTA plasma(n=5) | 96-105% | 92-105% | 86-97% | 78-90% |
heparin plasma(n=5) | 80-105% | 87-101% | 96-105% | 88-95% |
Stability of the High Sensitive ELISA Kit for Bovine Serum Albumin (BSA)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the High Sensitive ELISA Kit for Bovine Serum Albumin (BSA)
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
Test principle of the High Sensitive ELISA Kit for Bovine Serum Albumin (BSA)
This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to High Sensitive Bovine Serum Albumin (BSA) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled High Sensitive Bovine Serum Albumin (BSA) and unlabeled High Sensitive Bovine Serum Albumin (BSA) (Standards or samples) with the pre-coated antibody specific to High Sensitive Bovine Serum Albumin (BSA). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of High Sensitive Bovine Serum Albumin (BSA) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of High Sensitive Bovine Serum Albumin (BSA) in the sample.
GIVEAWAYS
INCREMENT SERVICES
Related products
Catalog No. | Organism species: Pan-species (General) | Applications (RESEARCH USE ONLY!) |
NPA248Ge01 | Native Bovine Serum Albumin (BSA) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA248Ge01 | Polyclonal Antibody to Bovine Serum Albumin (BSA) | WB; IHC; ICC; IP. |
MAA248Ge21 | Monoclonal Antibody to Bovine Serum Albumin (BSA) | WB; IHC; ICC; IP. |
LAA248Ge72 | Biotin-Linked Monoclonal Antibody to Bovine Serum Albumin (BSA) | WB; IHC; ICC. |
HEA248Ge | High Sensitive ELISA Kit for Bovine Serum Albumin (BSA) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEA248Ge | ELISA Kit for Bovine Serum Albumin (BSA) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CCA248Ge | CLIA Kit for Bovine Serum Albumin (BSA) | Chemiluminescent immunoassay for Antigen Detection. |
LMA248Ge | Multiplex Assay Kit for Bovine Serum Albumin (BSA) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |