ELISA Kit for Death receptor 5 (DR5)

CD262; TNFRSF10B; KILLER; TRAILR2; TRICK2; TRICK2A; TRICK2B; TRICKB; ZTNFR9; Death receptor 5; TNF-related apoptosis-inducing ligand receptor 2; Tumor Necrosis Factor Receptor Superfamily, Member 10B

  • ELISA Kit for Death receptor 5 (DR5) Packages (Simulation)
  • ELISA Kit for Death receptor 5 (DR5) Packages (Simulation)
  • ELISA Kit for Death receptor 5 (DR5) Results demonstration
  • SEA818Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Death receptor 5 (DR5)

This assay has high sensitivity and excellent specificity for detection of Death receptor 5 (DR5).
No significant cross-reactivity or interference between Death receptor 5 (DR5) and analogues was observed.

Recovery of the ELISA Kit for Death receptor 5 (DR5)

Matrices listed below were spiked with certain level of recombinant Death receptor 5 (DR5) and the recovery rates were calculated by comparing the measured value to the expected amount of Death receptor 5 (DR5) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 90-97 94
EDTA plasma(n=5) 96-103 101
heparin plasma(n=5) 96-103 99

Precision of the ELISA Kit for Death receptor 5 (DR5)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Death receptor 5 (DR5) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Death receptor 5 (DR5) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Death receptor 5 (DR5)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Death receptor 5 (DR5) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 97-105% 88-102% 98-105% 89-97%
EDTA plasma(n=5) 85-93% 78-91% 90-104% 93-101%
heparin plasma(n=5) 86-94% 96-105% 86-98% 91-105%

Stability of the ELISA Kit for Death receptor 5 (DR5)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Death receptor 5 (DR5)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Death receptor 5 (DR5)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Death receptor 5 (DR5). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Death receptor 5 (DR5). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Death receptor 5 (DR5), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Death receptor 5 (DR5) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPA818Hu03 Recombinant Death receptor 5 (DR5) Positive Control; Immunogen; SDS-PAGE; WB.
RPA818Hu01 Recombinant Death receptor 5 (DR5) Positive Control; Immunogen; SDS-PAGE; WB.
APA818Hu01 Active Death receptor 5 (DR5) Cell culture; Activity Assays.
RPA818Hu02 Recombinant Death receptor 5 (DR5) Positive Control; Immunogen; SDS-PAGE; WB.
PAA818Hu01 Polyclonal Antibody to Death receptor 5 (DR5) WB,IHC,ICC/IF
SEA818Hu ELISA Kit for Death receptor 5 (DR5) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA818Hu Multiplex Assay Kit for Death receptor 5 (DR5) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK