ELISA Kit for Serum Amyloid A (SAA)

SA-A; SAA1; PIG4; TP53I4; Amyloid protein A; Amyloid fibril protein AA; Serum amyloid A-1 protein

FOR IN VITRO AND RESEARCH USE ONLY, NOT FOR USE IN CLINICAL DIAGNOSTIC PROCEDURES!
  • ELISA Kit for Serum Amyloid A (SAA)Packages (Simulation)
  • ELISA Kit for Serum Amyloid A (SAA)Packages (Simulation)
  • ELISA Kit for Serum Amyloid A (SAA)Results demonstration
  • SEA885Eq.jpgTypical Standard Curve
  • CertificateISO9001: 2008, ISO13485: 2003 Registered

Specificity

This assay has high sensitivity and excellent specificity for detection of Serum Amyloid A (SAA).
No significant cross-reactivity or interference between Serum Amyloid A (SAA) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Serum Amyloid A (SAA) and the recovery rates were calculated by comparing the measured value to the expected amount of Serum Amyloid A (SAA) in samples.

MatrixRecovery range (%)Average(%)
serum(n=5)78-8883
EDTA plasma(n=5)86-10592
heparin plasma(n=5)83-10197

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Serum Amyloid A (SAA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Serum Amyloid A (SAA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Serum Amyloid A (SAA) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample1:21:41:81:16
serum(n=5)79-101%79-103%81-102%89-103%
EDTA plasma(n=5)92-101%85-103%95-103%80-101%
heparin plasma(n=5)96-103%92-101%92-101%90-99%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

ReagentsQuantityReagentsQuantity
Pre-coated, ready to use 96-well strip plate1Plate sealer for 96 wells4
Standard2Standard Diluent1×20mL
Detection Reagent A1×120µLAssay Diluent A1×12mL
Detection Reagent B1×120µLAssay Diluent B1×12mL
TMB Substrate1×9mLStop Solution1×6mL
Wash Buffer (30 × concentrate)1×20mLInstruction manual1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

ELISA Kit for Serum Amyloid A (SAA)

Test principle

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Serum Amyloid A (SAA). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Serum Amyloid A (SAA). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Serum Amyloid A (SAA), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Serum Amyloid A (SAA) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No.Organism species: Equus caballus; Equine (Horse)Applications
SEA885EqELISA Kit for Serum Amyloid A (SAA)Enzyme-linked immunosorbent assay for Antigen Detection.
GUESTBOOK