ELISA Kit for Complement Component 5a (C5a)

  • ELISA Kit for Complement Component 5a (C5a) Packages (Simulation)
  • ELISA Kit for Complement Component 5a (C5a) Packages (Simulation)
  • ELISA Kit for Complement Component 5a (C5a) Results demonstration
  • SEA388Ra.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Complement Component 5a (C5a)

This assay has high sensitivity and excellent specificity for detection of Complement Component 5a (C5a).
No significant cross-reactivity or interference between Complement Component 5a (C5a) and analogues was observed.

Recovery of the ELISA Kit for Complement Component 5a (C5a)

Matrices listed below were spiked with certain level of recombinant Complement Component 5a (C5a) and the recovery rates were calculated by comparing the measured value to the expected amount of Complement Component 5a (C5a) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 98-105 102
EDTA plasma(n=5) 82-101 91
heparin plasma(n=5) 91-105 97

Precision of the ELISA Kit for Complement Component 5a (C5a)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement Component 5a (C5a) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement Component 5a (C5a) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Complement Component 5a (C5a)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Complement Component 5a (C5a) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-93% 84-104% 88-103% 79-105%
EDTA plasma(n=5) 91-99% 97-104% 84-97% 92-101%
heparin plasma(n=5) 78-105% 91-98% 87-97% 90-101%

Stability of the ELISA Kit for Complement Component 5a (C5a)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Complement Component 5a (C5a)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Complement Component 5a (C5a)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Complement Component 5a (C5a). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Complement Component 5a (C5a). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Complement Component 5a (C5a), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Complement Component 5a (C5a) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
APA388Ra61 Active Complement Component 5a (C5a) Cell culture; Activity Assays.
EPA388Ra61 Eukaryotic Complement Component 5a (C5a) Positive Control; Immunogen; SDS-PAGE; WB.
RPA388Ra01 Recombinant Complement Component 5a (C5a) Positive Control; Immunogen; SDS-PAGE; WB.
RPA388Ra02 Recombinant Complement Component 5a (C5a) Positive Control; Immunogen; SDS-PAGE; WB.
PAA388Ra01 Polyclonal Antibody to Complement Component 5a (C5a) WB; IHC; ICC; IP.
PAA388Ra02 Polyclonal Antibody to Complement Component 5a (C5a) WB; IHC; ICC; IP.
PAA388Ra06 Polyclonal Antibody to Complement Component 5a (C5a) WB; IHC; ICC; IP.
LAA388Ra81 FITC-Linked Polyclonal Antibody to Complement Component 5a (C5a) WB; IHC; ICC; IF.
LAA388Ra71 Biotin-Linked Polyclonal Antibody to Complement Component 5a (C5a) WB; IHC; ICC.
MAA388Ra22 Monoclonal Antibody to Complement Component 5a (C5a) WB; IHC; ICC; IP.
MAA388Ra23 Monoclonal Antibody to Complement Component 5a (C5a) WB; IHC; ICC; IP.
MAA388Ra24 Monoclonal Antibody to Complement Component 5a (C5a) WB; IHC; ICC; IP.
MAA388Ra25 Monoclonal Antibody to Complement Component 5a (C5a) WB; IHC; ICC; IP.
MAA388Ra21 Monoclonal Antibody to Complement Component 5a (C5a) WB; IHC; ICC; IP.
SEA388Ra ELISA Kit for Complement Component 5a (C5a) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA388Ra CLIA Kit for Complement Component 5a (C5a) Chemiluminescent immunoassay for Antigen Detection.
LMA388Ra Multiplex Assay Kit for Complement Component 5a (C5a) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK