Specificity of the ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL)

This assay has high sensitivity and excellent specificity for detection of Oxidized Low Density Lipoprotein (OxLDL).
No significant cross-reactivity or interference between Oxidized Low Density Lipoprotein (OxLDL) and analogues was observed.

Recovery of the ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL)

Matrices listed below were spiked with certain level of recombinant Oxidized Low Density Lipoprotein (OxLDL) and the recovery rates were calculated by comparing the measured value to the expected amount of Oxidized Low Density Lipoprotein (OxLDL) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 87-97 92
EDTA plasma(n=5) 99-105 102
heparin plasma(n=5) 78-89 85

Precision of the ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Oxidized Low Density Lipoprotein (OxLDL) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Oxidized Low Density Lipoprotein (OxLDL) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Oxidized Low Density Lipoprotein (OxLDL) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-94% 85-98% 85-95% 92-105%
EDTA plasma(n=5) 95-102% 98-105% 95-105% 79-102%
heparin plasma(n=5) 91-105% 93-101% 91-104% 90-104%

Stability of the ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL)

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.

Test principle of the ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL)

This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Oxidized Low Density Lipoprotein (OxLDL) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Oxidized Low Density Lipoprotein (OxLDL) and unlabeled Oxidized Low Density Lipoprotein (OxLDL) (Standards or samples) with the pre-coated antibody specific to Oxidized Low Density Lipoprotein (OxLDL). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Oxidized Low Density Lipoprotein (OxLDL) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Oxidized Low Density Lipoprotein (OxLDL) in the sample.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
SPA527Hu01 Synthetic Oxidized Low Density Lipoprotein (OxLDL) Immunogen; Blocking Peptide.
PAA527Hu08 Polyclonal Antibody to Oxidized Low Density Lipoprotein (OxLDL) IHC; ICC; IP
SEA527Hu ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL) Enzyme-linked immunosorbent assay for Antigen Detection.
CEA527Hu ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA527Hu Multiplex Assay Kit for Oxidized Low Density Lipoprotein (OxLDL) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
PSA527Hu11 Antibody Pair for Oxidized Low Density Lipoprotein (OxLDL) ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays.
KSA527Hu11 ELISA Kit DIY Materials for Oxidized Low Density Lipoprotein (OxLDL) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK