ELISA Kit for Thymic Stromal Lymphopoietin (TSLP)

  • ELISA Kit for Thymic Stromal Lymphopoietin (TSLP) Packages (Simulation)
  • ELISA Kit for Thymic Stromal Lymphopoietin (TSLP) Packages (Simulation)
  • ELISA Kit for Thymic Stromal Lymphopoietin (TSLP) Results demonstration
  • SEB320Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Thymic Stromal Lymphopoietin (TSLP)

This assay has high sensitivity and excellent specificity for detection of Thymic Stromal Lymphopoietin (TSLP).
No significant cross-reactivity or interference between Thymic Stromal Lymphopoietin (TSLP) and analogues was observed.

Recovery of the ELISA Kit for Thymic Stromal Lymphopoietin (TSLP)

Matrices listed below were spiked with certain level of recombinant Thymic Stromal Lymphopoietin (TSLP) and the recovery rates were calculated by comparing the measured value to the expected amount of Thymic Stromal Lymphopoietin (TSLP) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 87-97 93
EDTA plasma(n=5) 84-103 88
heparin plasma(n=5) 85-94 90

Precision of the ELISA Kit for Thymic Stromal Lymphopoietin (TSLP)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Thymic Stromal Lymphopoietin (TSLP) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Thymic Stromal Lymphopoietin (TSLP) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Thymic Stromal Lymphopoietin (TSLP)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Thymic Stromal Lymphopoietin (TSLP) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-101% 95-102% 79-101% 82-98%
EDTA plasma(n=5) 96-103% 89-98% 78-93% 95-105%
heparin plasma(n=5) 91-98% 95-102% 90-104% 88-97%

Stability of the ELISA Kit for Thymic Stromal Lymphopoietin (TSLP)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Thymic Stromal Lymphopoietin (TSLP)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Thymic Stromal Lymphopoietin (TSLP)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Thymic Stromal Lymphopoietin (TSLP). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Thymic Stromal Lymphopoietin (TSLP). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Thymic Stromal Lymphopoietin (TSLP), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Thymic Stromal Lymphopoietin (TSLP) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPB320Hu02 Recombinant Thymic Stromal Lymphopoietin (TSLP) Positive Control; Immunogen; SDS-PAGE; WB.
RPB320Hu03 Recombinant Thymic Stromal Lymphopoietin (TSLP) Positive Control; Immunogen; SDS-PAGE; WB.
RPB320Hu01 Recombinant Thymic Stromal Lymphopoietin (TSLP) Positive Control; Immunogen; SDS-PAGE; WB.
APB320Hu01 Active Thymic Stromal Lymphopoietin (TSLP) Cell culture; Activity Assays.
PAB320Hu01 Polyclonal Antibody to Thymic Stromal Lymphopoietin (TSLP) WB; IHC; ICC; IP.
MAB320Hu22 Monoclonal Antibody to Thymic Stromal Lymphopoietin (TSLP) WB; IHC; ICC; IP.
MAB320Hu27 Monoclonal Antibody to Thymic Stromal Lymphopoietin (TSLP) WB; IHC; ICC; IP.
MAB320Hu29 Monoclonal Antibody to Thymic Stromal Lymphopoietin (TSLP) WB; IHC; ICC; IP.
MAB320Hu21 Monoclonal Antibody to Thymic Stromal Lymphopoietin (TSLP) WB; IHC; ICC; IP.
MAB320Hu23 Monoclonal Antibody to Thymic Stromal Lymphopoietin (TSLP) WB; IHC; ICC; IP.
MAB320Hu24 Monoclonal Antibody to Thymic Stromal Lymphopoietin (TSLP) WB; IHC; ICC; IP.
MAB320Hu25 Monoclonal Antibody to Thymic Stromal Lymphopoietin (TSLP) WB; IHC; ICC; IP.
HEB320Hu High Sensitive ELISA Kit for Thymic Stromal Lymphopoietin (TSLP) Enzyme-linked immunosorbent assay for Antigen Detection.
SEB320Hu ELISA Kit for Thymic Stromal Lymphopoietin (TSLP) Enzyme-linked immunosorbent assay for Antigen Detection.
SCB320Hu CLIA Kit for Thymic Stromal Lymphopoietin (TSLP) Chemiluminescent immunoassay for Antigen Detection.
LMB320Hu Multiplex Assay Kit for Thymic Stromal Lymphopoietin (TSLP) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK