ELISA Kit for Myoglobin (MYO)

PVALB; MB

  • ELISA Kit for Myoglobin (MYO) Packages (Simulation)
  • ELISA Kit for Myoglobin (MYO) Packages (Simulation)
  • ELISA Kit for Myoglobin (MYO) Results demonstration
  • SEA480Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Myoglobin (MYO)

This assay has high sensitivity and excellent specificity for detection of Myoglobin (MYO).
No significant cross-reactivity or interference between Myoglobin (MYO) and analogues was observed.

Recovery of the ELISA Kit for Myoglobin (MYO)

Matrices listed below were spiked with certain level of recombinant Myoglobin (MYO) and the recovery rates were calculated by comparing the measured value to the expected amount of Myoglobin (MYO) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 93-101 96
EDTA plasma(n=5) 95-102 98
heparin plasma(n=5) 78-90 81

Precision of the ELISA Kit for Myoglobin (MYO)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Myoglobin (MYO) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Myoglobin (MYO) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Myoglobin (MYO)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Myoglobin (MYO) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 89-104% 90-101% 93-102% 84-101%
EDTA plasma(n=5) 79-105% 82-102% 86-99% 88-103%
heparin plasma(n=5) 86-93% 84-99% 93-105% 86-98%

Stability of the ELISA Kit for Myoglobin (MYO)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Myoglobin (MYO)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Myoglobin (MYO)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Myoglobin (MYO). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Myoglobin (MYO). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Myoglobin (MYO), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Myoglobin (MYO) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPA480Hu01 Recombinant Myoglobin (MYO) Positive Control; Immunogen; SDS-PAGE; WB.
RPA480Hu02 Recombinant Myoglobin (MYO) Positive Control; Immunogen; SDS-PAGE; WB.
APA480Hu01 Active Myoglobin (MYO) Cell culture; Activity Assays.
PAA480Hu01 Polyclonal Antibody to Myoglobin (MYO) WB; IHC; ICC; IP.
PAA480Hu02 Polyclonal Antibody to Myoglobin (MYO) WB; IHC; ICC; IP.
LAA480Hu81 FITC-Linked Polyclonal Antibody to Myoglobin (MYO) WB; IHC; ICC; IF.
LAA480Hu71 Biotin-Linked Polyclonal Antibody to Myoglobin (MYO) WB; IHC; ICC.
MAA480Hu26 Monoclonal Antibody to Myoglobin (MYO) WB; IHC; ICC; IP.
MAA480Hu28 Monoclonal Antibody to Myoglobin (MYO) WB; IHC; ICC; IP.
MAA480Hu23 Monoclonal Antibody to Myoglobin (MYO) WB; IHC; ICC; IP.
MAA480Hu21 Monoclonal Antibody to Myoglobin (MYO) WB; IHC; ICC; IP.
MAA480Hu25 Monoclonal Antibody to Myoglobin (MYO) WB; IHC; ICC; IP.
MAA480Hu24 Monoclonal Antibody to Myoglobin (MYO) WB; IHC; ICC; IP.
MAA480Hu27 Monoclonal Antibody to Myoglobin (MYO) WB; IHC; ICC; IP.
MAA480Hu29 Monoclonal Antibody to Myoglobin (MYO) WB; IHC; ICC; IP.
MAA480Hu22 Monoclonal Antibody to Myoglobin (MYO) WB; IHC; ICC; IP.
FAA480Hu04 Anti-Myoglobin (MYO) Monoclonal Antibody Flow cytometry.
FAA480Hu02 Anti-Myoglobin (MYO) Monoclonal Antibody Flow cytometry.
SEA480Hu ELISA Kit for Myoglobin (MYO) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA480Hu CLIA Kit for Myoglobin (MYO) Chemiluminescent immunoassay for Antigen Detection.
LMA480Hu Multiplex Assay Kit for Myoglobin (MYO) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA480Hu01 ELISA Kit DIY Materials for Myoglobin (MYO) Main materials for "Do It (ELISA Kit) Yourself".