ELISA Kit for Monocyte Chemotactic Protein 3 (MCP3)

CCL7; FIC; MARC; NC28; MCP3; SCYA7; Chemokine C-C-Motif Ligand 7; Small Inducible Cytokine A7; Monocyte Chemoattractant Protein 3

FOR IN VITRO AND RESEARCH USE ONLY, NOT FOR USE IN CLINICAL DIAGNOSTIC PROCEDURES!
  • ELISA Kit for Monocyte Chemotactic Protein 3 (MCP3)Packages (Simulation)
  • ELISA Kit for Monocyte Chemotactic Protein 3 (MCP3)Packages (Simulation)
  • ELISA Kit for Monocyte Chemotactic Protein 3 (MCP3)Results demonstration
  • SEA089Hu.jpgTypical Standard Curve
  • CertificateISO9001: 2008, ISO13485: 2003 Registered

Specificity

This assay has high sensitivity and excellent specificity for detection of Monocyte Chemotactic Protein 3 (MCP3).
No significant cross-reactivity or interference between Monocyte Chemotactic Protein 3 (MCP3) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Monocyte Chemotactic Protein 3 (MCP3) and the recovery rates were calculated by comparing the measured value to the expected amount of Monocyte Chemotactic Protein 3 (MCP3) in samples.

MatrixRecovery range (%)Average(%)
serum(n=5)90-104101
EDTA plasma(n=5)95-10299
heparin plasma(n=5)78-9787

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Monocyte Chemotactic Protein 3 (MCP3) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Monocyte Chemotactic Protein 3 (MCP3) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Monocyte Chemotactic Protein 3 (MCP3) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample1:21:41:81:16
serum(n=5)80-88%97-105%90-102%89-97%
EDTA plasma(n=5)94-105%90-101%94-105%80-101%
heparin plasma(n=5)88-102%97-104%81-102%99-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

ReagentsQuantityReagentsQuantity
Pre-coated, ready to use 96-well strip plate1Plate sealer for 96 wells4
Standard2Standard Diluent1×20mL
Detection Reagent A1×120µLAssay Diluent A1×12mL
Detection Reagent B1×120µLAssay Diluent B1×12mL
TMB Substrate1×9mLStop Solution1×6mL
Wash Buffer (30 × concentrate)1×20mLInstruction manual1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

ELISA Kit for Monocyte Chemotactic Protein 3 (MCP3)

Test principle

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Monocyte Chemotactic Protein 3 (MCP3). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Monocyte Chemotactic Protein 3 (MCP3). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Monocyte Chemotactic Protein 3 (MCP3), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Monocyte Chemotactic Protein 3 (MCP3) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No.Organism species: Homo sapiens (Human)Applications
APA089Hu01Active Monocyte Chemotactic Protein 3 (MCP3)Cell culture; Activity Assays.
RPA089Hu01Recombinant Monocyte Chemotactic Protein 3 (MCP3)Positive Control; Immunogen; SDS-PAGE; WB.
PAA089Hu01Polyclonal Antibody to Monocyte Chemotactic Protein 3 (MCP3)WB; IHC; ICC; IP.
MAA089Hu22Monoclonal Antibody to Monocyte Chemotactic Protein 3 (MCP3)WB; IHC; ICC; IP.
SEA089HuELISA Kit for Monocyte Chemotactic Protein 3 (MCP3)Enzyme-linked immunosorbent assay for Antigen Detection.
SCA089HuCLIA Kit for Monocyte Chemotactic Protein 3 (MCP3)Chemiluminescent immunoassay for Antigen Detection.
KSA089Hu01ELISA Kit DIY Materials for Monocyte Chemotactic Protein 3 (MCP3)Main materials for "Do It(ELISA Kit) Yourself"