ELISA Kit for Glycogen Phosphorylase, Liver (PYGL)

GPLL; GPBB; Hers Disease; Glycogen Storage Disease Type VI

  • ELISA Kit for Glycogen Phosphorylase, Liver (PYGL) Packages (Simulation)
  • ELISA Kit for Glycogen Phosphorylase, Liver (PYGL) Packages (Simulation)
  • ELISA Kit for Glycogen Phosphorylase, Liver (PYGL) Results demonstration
  • SEA849Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Glycogen Phosphorylase, Liver (PYGL)

This assay has high sensitivity and excellent specificity for detection of Glycogen Phosphorylase, Liver (PYGL).
No significant cross-reactivity or interference between Glycogen Phosphorylase, Liver (PYGL) and analogues was observed.

Recovery of the ELISA Kit for Glycogen Phosphorylase, Liver (PYGL)

Matrices listed below were spiked with certain level of recombinant Glycogen Phosphorylase, Liver (PYGL) and the recovery rates were calculated by comparing the measured value to the expected amount of Glycogen Phosphorylase, Liver (PYGL) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-95 85
EDTA plasma(n=5) 96-105 101
heparin plasma(n=5) 89-99 93

Precision of the ELISA Kit for Glycogen Phosphorylase, Liver (PYGL)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glycogen Phosphorylase, Liver (PYGL) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glycogen Phosphorylase, Liver (PYGL) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Glycogen Phosphorylase, Liver (PYGL)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glycogen Phosphorylase, Liver (PYGL) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-101% 87-98% 90-98% 83-94%
EDTA plasma(n=5) 85-103% 91-102% 82-97% 84-92%
heparin plasma(n=5) 78-98% 99-105% 81-105% 92-99%

Stability of the ELISA Kit for Glycogen Phosphorylase, Liver (PYGL)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Glycogen Phosphorylase, Liver (PYGL)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Glycogen Phosphorylase, Liver (PYGL)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Glycogen Phosphorylase, Liver (PYGL). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Glycogen Phosphorylase, Liver (PYGL). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Glycogen Phosphorylase, Liver (PYGL), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Glycogen Phosphorylase, Liver (PYGL) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPA849Hu01 Recombinant Glycogen Phosphorylase, Liver (PYGL) Positive Control; Immunogen; SDS-PAGE; WB.
RPA849Hu02 Recombinant Glycogen Phosphorylase, Liver (PYGL) Positive Control; Immunogen; SDS-PAGE; WB.
PAA849Hu02 Polyclonal Antibody to Glycogen Phosphorylase, Liver (PYGL) WB,IHC
PAA849Hu01 Polyclonal Antibody to Glycogen Phosphorylase, Liver (PYGL) WB; IHC; ICC; IP.
LAA849Hu71 Biotin-Linked Polyclonal Antibody to Glycogen Phosphorylase, Liver (PYGL) WB; IHC; ICC.
MAA849Hu22 Monoclonal Antibody to Glycogen Phosphorylase, Liver (PYGL) WB; IHC; ICC; IP.
SEA849Hu ELISA Kit for Glycogen Phosphorylase, Liver (PYGL) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA849Hu Multiplex Assay Kit for Glycogen Phosphorylase, Liver (PYGL) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK