ELISA Kit for Calreticulin (CRT)

CALR; RO; SSA; CC1qR; ERp60; HACBP; grp60; CRTC; CRP55; Calregulin; Sicca Syndrome Antigen A; Autoantigen Ro; Endoplasmic reticulum resident protein 60

  • ELISA Kit for Calreticulin (CRT)Packages (Simulation)
  • ELISA Kit for Calreticulin (CRT)Packages (Simulation)
  • ELISA Kit for Calreticulin (CRT)Results demonstration
  • SEB486Hu.jpgTypical Standard Curve
  • CertificateISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Calreticulin (CRT)

This assay has high sensitivity and excellent specificity for detection of Calreticulin (CRT).
No significant cross-reactivity or interference between Calreticulin (CRT) and analogues was observed.

Recovery of the ELISA Kit for Calreticulin (CRT)

Matrices listed below were spiked with certain level of recombinantCalreticulin (CRT) and the recovery rates were calculated by comparing the measured value to the expected amount of Calreticulin (CRT) in samples.

MatrixRecovery range (%)Average(%)
serum(n=5)97-104101
EDTA plasma(n=5)86-9390
heparin plasma(n=5)90-9895

Precision of the ELISA Kit for Calreticulin (CRT)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Calreticulin (CRT) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Calreticulin (CRT) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Calreticulin (CRT)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Calreticulin (CRT) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample1:21:41:81:16
serum(n=5)79-104%86-99%96-105%78-93%
EDTA plasma(n=5)82-91%97-105%93-101%88-95%
heparin plasma(n=5)80-102%80-104%96-105%80-96%

Stability of the ELISA Kit for Calreticulin (CRT)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided of the ELISA Kit for Calreticulin (CRT)

ReagentsQuantityReagentsQuantity
Pre-coated, ready to use 96-well strip plate1Plate sealer for 96 wells4
Standard2Standard Diluent1×20mL
Detection Reagent A1×120µLAssay Diluent A1×12mL
Detection Reagent B1×120µLAssay Diluent B1×12mL
TMB Substrate1×9mLStop Solution1×6mL
Wash Buffer (30 × concentrate)1×20mLInstruction manual1

Assay procedure summary of the ELISA Kit for Calreticulin (CRT)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

ELISA Kit for Calreticulin (CRT)

Test principle of the ELISA Kit for Calreticulin (CRT)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Calreticulin (CRT). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Calreticulin (CRT). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Calreticulin (CRT), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Calreticulin (CRT) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No.Organism species: Homo sapiens (Human)Applications (RESEARCH USE ONLY!)
APB486Hu61Active Calreticulin (CRT)Cell culture; Activity Assays.
EPB486Hu61Eukaryotic Calreticulin (CRT)Positive Control; Immunogen; SDS-PAGE; WB.
RPB486Hu02Recombinant Calreticulin (CRT)Positive Control; Immunogen; SDS-PAGE; WB.
RPB486Hu01Recombinant Calreticulin (CRT)Positive Control; Immunogen; SDS-PAGE; WB.
CPB486Hu21OVA Conjugated Calreticulin (CRT)Immunogen; SDS-PAGE; WB.
PAB486Hu02Polyclonal Antibody to Calreticulin (CRT)WB; IHC; ICC; IP.
PAB486Hu01Polyclonal Antibody to Calreticulin (CRT)WB; IHC; ICC; IP.
PAB486Hu08Polyclonal Antibody to Calreticulin (CRT)WB; IHC; ICC; IP.
LAB486Hu71Biotin-Linked Polyclonal Antibody to Calreticulin (CRT)WB; IHC; ICC.
MAB486Hu22Monoclonal Antibody to Calreticulin (CRT)WB; IHC; ICC; IP.
SEB486HuELISA Kit for Calreticulin (CRT)Enzyme-linked immunosorbent assay for Antigen Detection.
CEB486HuELISA Kit for Calreticulin (CRT)Enzyme-linked immunosorbent assay for Antigen Detection.
KSB486Hu01ELISA Kit DIY Materials for Calreticulin (CRT)Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK