ELISA Kit for Histone Cluster 1, H4a (HIST1H4A)

H4FA; HIST2H4B; HIST2H4C; HIST2H4D; HIST2H4E; HIST2H4F; HIST2H4G; HIST2H4H; HIST2H4I; HIST2H4J; HIST2H4K; HIST2H4B; HIST4H4; HIST2H4A

  • ELISA Kit for Histone Cluster 1, H4a (HIST1H4A) Packages (Simulation)
  • ELISA Kit for Histone Cluster 1, H4a (HIST1H4A) Packages (Simulation)
  • ELISA Kit for Histone Cluster 1, H4a (HIST1H4A) Results demonstration
  • SEQ004Bo.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Histone Cluster 1, H4a (HIST1H4A)

This assay has high sensitivity and excellent specificity for detection of Histone Cluster 1, H4a (HIST1H4A).
No significant cross-reactivity or interference between Histone Cluster 1, H4a (HIST1H4A) and analogues was observed.

Precision of the ELISA Kit for Histone Cluster 1, H4a (HIST1H4A)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Histone Cluster 1, H4a (HIST1H4A) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Histone Cluster 1, H4a (HIST1H4A) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability of the ELISA Kit for Histone Cluster 1, H4a (HIST1H4A)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Histone Cluster 1, H4a (HIST1H4A)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Histone Cluster 1, H4a (HIST1H4A)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Histone Cluster 1, H4a (HIST1H4A). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Histone Cluster 1, H4a (HIST1H4A). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Histone Cluster 1, H4a (HIST1H4A), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Histone Cluster 1, H4a (HIST1H4A) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Bos taurus; Bovine (Cattle) Applications (RESEARCH USE ONLY!)
RPQ004Bo01 Recombinant Histone Cluster 1, H4a (HIST1H4A) Positive Control; Immunogen; SDS-PAGE; WB.
PAQ004Bo01 Polyclonal Antibody to Histone Cluster 1, H4a (HIST1H4A) WB; IHC
SEQ004Bo ELISA Kit for Histone Cluster 1, H4a (HIST1H4A) Enzyme-linked immunosorbent assay for Antigen Detection.
LMQ004Bo Multiplex Assay Kit for Histone Cluster 1, H4a (HIST1H4A) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSQ004Bo01 ELISA Kit DIY Materials for Histone Cluster 1, H4a (HIST1H4A) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK