ELISA Kit for Anti-Mannose Binding Lectin Antibody (Anti-MBL)

MBL2; COLEC1; HSMBPC; MBP1; MBP; Collectin-1; Mannose-binding protein C; Mannan Binding Protein; Mannose-Binding Lectin(Protein C)2,Soluble(Opsonic Defect)

  • ELISA Kit for Anti-Mannose Binding Lectin Antibody (Anti-MBL) Packages (Simulation)
  • ELISA Kit for Anti-Mannose Binding Lectin Antibody (Anti-MBL) Packages (Simulation)
  • ELISA Kit for Anti-Mannose Binding Lectin Antibody (Anti-MBL) Results demonstration
  • AEB480Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Anti-Mannose Binding Lectin Antibody (Anti-MBL)

This assay has high sensitivity and excellent specificity for detection of Anti-Mannose Binding Lectin Antibody (Anti-MBL).
No significant cross-reactivity or interference between Anti-Mannose Binding Lectin Antibody (Anti-MBL) and analogues was observed.

Recovery of the ELISA Kit for Anti-Mannose Binding Lectin Antibody (Anti-MBL)

Matrices listed below were spiked with certain level of Anti-Mannose Binding Lectin Antibody (Anti-MBL) and the recovery rates were calculated by comparing the measured value to the expected amount of Anti-Mannose Binding Lectin Antibody (Anti-MBL) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-104 101
EDTA plasma(n=5) 79-104 99
heparin plasma(n=5) 81-105 92

Precision of the ELISA Kit for Anti-Mannose Binding Lectin Antibody (Anti-MBL)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Anti-Mannose Binding Lectin Antibody (Anti-MBL) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Anti-Mannose Binding Lectin Antibody (Anti-MBL) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Anti-Mannose Binding Lectin Antibody (Anti-MBL)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Anti-Mannose Binding Lectin Antibody (Anti-MBL) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 83-97% 97-105% 93-101% 93-101%
EDTA plasma(n=5) 86-93% 93-103% 83-104% 95-103%
heparin plasma(n=5) 95-103% 80-103% 79-98% 80-101%

Stability of the ELISA Kit for Anti-Mannose Binding Lectin Antibody (Anti-MBL)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Anti-Mannose Binding Lectin Antibody (Anti-MBL)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 5 times;
5. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
6. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Anti-Mannose Binding Lectin Antibody (Anti-MBL)

The microtiter plate provided in this kit has been pre-coated with an antigen. Standards or samples are then added to the appropriate microtiter plate wells with a Horseradish Peroxidase (HRP)-conjugated secondary antibody. After TMB substrate solution is added, those wells that contain Anti-Mannose Binding Lectin Antibody (Anti-MBL) will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Anti-Mannose Binding Lectin Antibody (Anti-MBL) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPB480Hu02 Recombinant Mannose Binding Lectin (MBL) Positive Control; Immunogen; SDS-PAGE; WB.
APB480Hu02 Active Mannose Binding Lectin (MBL) Cell culture; Activity Assays.
APB480Hu61 Active Mannose Binding Lectin (MBL) Cell culture; Activity Assays.
EPB480Hu61 Eukaryotic Mannose Binding Lectin (MBL) Positive Control; Immunogen; SDS-PAGE; WB.
RPB480Hu03 Recombinant Mannose Binding Lectin (MBL) Positive Control; Immunogen; SDS-PAGE; WB.
RPB480Hu01 Recombinant Mannose Binding Lectin (MBL) Positive Control; Immunogen; SDS-PAGE; WB.
PAB480Hu02 Polyclonal Antibody to Mannose Binding Lectin (MBL) WB; IHC; ICC; IP.
PAB480Hu01 Polyclonal Antibody to Mannose Binding Lectin (MBL) WB; IHC; ICC; IP.
PAB480Hu03 Polyclonal Antibody to Mannose Binding Lectin (MBL) WB; IHC; ICC; IP.
LAB480Hu71 Biotin-Linked Polyclonal Antibody to Mannose Binding Lectin (MBL) WB; IHC; ICC.
MAB480Hu22 Monoclonal Antibody to Mannose Binding Lectin (MBL) WB; IHC; ICC; IP.
SEB480Hu ELISA Kit for Mannose Binding Lectin (MBL) Enzyme-linked immunosorbent assay for Antigen Detection.
AEB480Hu ELISA Kit for Anti-Mannose Binding Lectin Antibody (Anti-MBL) Enzyme-linked immunosorbent assay for Antibody Detection.
LMB480Hu Multiplex Assay Kit for Mannose Binding Lectin (MBL) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSB480Hu01 ELISA Kit DIY Materials for Mannose Binding Lectin (MBL) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK