CLIA Kit for Ubiquitin Conjugating Enzyme E2L3 (UBE2L3)

L-UBC; E2-F1; UBCH7; UbcM4; Ubiquitin carrier protein L3; Ubiquitin-conjugating enzyme E2-F1; Ubiquitin-protein ligase L3

  • CLIA Kit for Ubiquitin Conjugating Enzyme E2L3 (UBE2L3) Packages (Simulation)
  • CLIA Kit for Ubiquitin Conjugating Enzyme E2L3 (UBE2L3) Packages (Simulation)
  • CLIA Kit for Ubiquitin Conjugating Enzyme E2L3 (UBE2L3) Results demonstration
  • SCE602Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Ubiquitin Conjugating Enzyme E2L3 (UBE2L3)

This assay has high sensitivity and excellent specificity for detection of Ubiquitin Conjugating Enzyme E2L3 (UBE2L3).
No significant cross-reactivity or interference between Ubiquitin Conjugating Enzyme E2L3 (UBE2L3) and analogues was observed.

Precision of the CLIA Kit for Ubiquitin Conjugating Enzyme E2L3 (UBE2L3)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ubiquitin Conjugating Enzyme E2L3 (UBE2L3) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ubiquitin Conjugating Enzyme E2L3 (UBE2L3) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability of the CLIA Kit for Ubiquitin Conjugating Enzyme E2L3 (UBE2L3)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Ubiquitin Conjugating Enzyme E2L3 (UBE2L3)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Ubiquitin Conjugating Enzyme E2L3 (UBE2L3)

The microplate provided in this kit has been pre-coated with an antibody specific to Ubiquitin Conjugating Enzyme E2L3 (UBE2L3). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Ubiquitin Conjugating Enzyme E2L3 (UBE2L3). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Ubiquitin Conjugating Enzyme E2L3 (UBE2L3) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPE602Hu01 Recombinant Ubiquitin Conjugating Enzyme E2L3 (UBE2L3) Positive Control; Immunogen; SDS-PAGE; WB.
PAE602Hu01 Polyclonal Antibody to Ubiquitin Conjugating Enzyme E2L3 (UBE2L3) WB; IHC; ICC; IP.
MAE602Hu21 Monoclonal Antibody to Ubiquitin Conjugating Enzyme E2L3 (UBE2L3) WB; IHC; ICC; IP.
SEE602Hu ELISA Kit for Ubiquitin Conjugating Enzyme E2L3 (UBE2L3) Enzyme-linked immunosorbent assay for Antigen Detection.
SCE602Hu CLIA Kit for Ubiquitin Conjugating Enzyme E2L3 (UBE2L3) Chemiluminescent immunoassay for Antigen Detection.
LME602Hu Multiplex Assay Kit for Ubiquitin Conjugating Enzyme E2L3 (UBE2L3) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK