CLIA Kit for Stem Cell Factor (SCF)

KITLG; MGF; SF; KL1; Kitl; FPH2; Kit-Ligand; Steel Factor; Mast Cell Growth Factor; Steel factor; Familial Progressive Hyperpigmentation 2

  • CLIA Kit for Stem Cell Factor (SCF) Packages (Simulation)
  • CLIA Kit for Stem Cell Factor (SCF) Packages (Simulation)
  • CLIA Kit for Stem Cell Factor (SCF) Results demonstration
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Stem Cell Factor (SCF)

This assay has high sensitivity and excellent specificity for detection of Stem Cell Factor (SCF).
No significant cross-reactivity or interference between Stem Cell Factor (SCF) and analogues was observed.

Recovery of the CLIA Kit for Stem Cell Factor (SCF)

Matrices listed below were spiked with certain level of recombinant Stem Cell Factor (SCF) and the recovery rates were calculated by comparing the measured value to the expected amount of Stem Cell Factor (SCF) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-90 84
EDTA plasma(n=5) 81-89 84
heparin plasma(n=5) 80-96 92

Precision of the CLIA Kit for Stem Cell Factor (SCF)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Stem Cell Factor (SCF) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Stem Cell Factor (SCF) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Stem Cell Factor (SCF)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Stem Cell Factor (SCF) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 90-101% 91-98% 93-101% 94-105%
EDTA plasma(n=5) 88-99% 98-105% 79-99% 80-104%
heparin plasma(n=5) 88-104% 78-102% 85-99% 87-101%

Stability of the CLIA Kit for Stem Cell Factor (SCF)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Stem Cell Factor (SCF)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Stem Cell Factor (SCF)

The microplate provided in this kit has been pre-coated with an antibody specific to Stem Cell Factor (SCF). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Stem Cell Factor (SCF). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Stem Cell Factor (SCF) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
EPA120Hu61 Eukaryotic Stem Cell Factor (SCF) Positive Control; Immunogen; SDS-PAGE; WB.
RPA120Hu01 Recombinant Stem Cell Factor (SCF) Positive Control; Immunogen; SDS-PAGE; WB.
APA120Hu01 Active Stem Cell Factor (SCF) Cell culture; Activity Assays.
PAA120Hu01 Polyclonal Antibody to Stem Cell Factor (SCF) WB; IHC; ICC; IP.
MAA120Hu22 Monoclonal Antibody to Stem Cell Factor (SCF) WB; IHC; ICC; IP.
MEA120Hu Mini Samples ELISA Kit for Stem Cell Factor (SCF) Enzyme-linked immunosorbent assay for Antigen Detection.
SEA120Hu ELISA Kit for Stem Cell Factor (SCF) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA120Hu CLIA Kit for Stem Cell Factor (SCF) Chemiluminescent immunoassay for Antigen Detection.
LMA120Hu Multiplex Assay Kit for Stem Cell Factor (SCF) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA120Hu01 ELISA Kit DIY Materials for Stem Cell Factor (SCF) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK