CLIA Kit for E-selectin

CD62E; CD62-E; E-Selectin; ELAM; ELAM1; ESEL; SEL-E; E-LAM; E-LAM1; E-SEL; LECAM2; Endothelial Leukocyte Adhesion Molecule 1; CD62 Antigen-Like Family Member E

  • CLIA Kit for E-selectin Packages (Simulation)
  • CLIA Kit for E-selectin Packages (Simulation)
  • CLIA Kit for E-selectin Results demonstration
  • SCA029Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for E-selectin

This assay has high sensitivity and excellent specificity for detection of E-selectin.
No significant cross-reactivity or interference between E-selectin and analogues was observed.

Recovery of the CLIA Kit for E-selectin

Matrices listed below were spiked with certain level of recombinant E-selectin and the recovery rates were calculated by comparing the measured value to the expected amount of E-selectin in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 81-94 90
EDTA plasma(n=5) 78-101 97
heparin plasma(n=5) 90-99 95

Precision of the CLIA Kit for E-selectin

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level E-selectin were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level E-selectin were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for E-selectin

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of E-selectin and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-90% 83-97% 78-101% 79-96%
EDTA plasma(n=5) 95-102% 98-105% 95-105% 79-102%
heparin plasma(n=5) 96-104% 80-101% 92-101% 85-92%

Stability of the CLIA Kit for E-selectin

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for E-selectin

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for E-selectin

The microplate provided in this kit has been pre-coated with an antibody specific to E-selectin. Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to E-selectin. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the E-selectin level in the sample or standard.;

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPA029Mu02 Recombinant E-selectin Positive Control; Immunogen; SDS-PAGE; WB.
RPA029Mu01 Recombinant E-selectin Positive Control; Immunogen; SDS-PAGE; WB.
PAA029Mu02 Polyclonal Antibody to E-selectin WB; IHC; ICC; IP.
PAA029Mu01 Polyclonal Antibody to E-selectin WB; IHC; ICC; IP.
SEA029Mu ELISA Kit for E-selectin Enzyme-linked immunosorbent assay for Antigen Detection.
SCA029Mu CLIA Kit for E-selectin Chemiluminescent immunoassay for Antigen Detection.
LMA029Mu Multiplex Assay Kit for E-selectin ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA029Mu01 ELISA Kit DIY Materials for E-selectin Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK