CLIA Kit for Secondary Lymphoid Tissue Chemokine (SLC)

CCL21; 6Ckine; CKb9; ECL; SCYA21; TCA4; ECL; Chemokine(C-C-Motif)Ligand 21; Beta Chemokine Exodus-2; Efficient Chemoattractant For Lymphocytes

  • CLIA Kit for Secondary Lymphoid Tissue Chemokine (SLC) Packages (Simulation)
  • CLIA Kit for Secondary Lymphoid Tissue Chemokine (SLC) Packages (Simulation)
  • CLIA Kit for Secondary Lymphoid Tissue Chemokine (SLC) Results demonstration
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Secondary Lymphoid Tissue Chemokine (SLC)

This assay has high sensitivity and excellent specificity for detection of Secondary Lymphoid Tissue Chemokine (SLC).
No significant cross-reactivity or interference between Secondary Lymphoid Tissue Chemokine (SLC) and analogues was observed.

Recovery of the CLIA Kit for Secondary Lymphoid Tissue Chemokine (SLC)

Matrices listed below were spiked with certain level of recombinant Secondary Lymphoid Tissue Chemokine (SLC) and the recovery rates were calculated by comparing the measured value to the expected amount of Secondary Lymphoid Tissue Chemokine (SLC) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 87-95 90
EDTA plasma(n=5) 92-101 95
heparin plasma(n=5) 90-104 93

Precision of the CLIA Kit for Secondary Lymphoid Tissue Chemokine (SLC)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Secondary Lymphoid Tissue Chemokine (SLC) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Secondary Lymphoid Tissue Chemokine (SLC) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Secondary Lymphoid Tissue Chemokine (SLC)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Secondary Lymphoid Tissue Chemokine (SLC) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-101% 86-94% 91-98% 91-99%
EDTA plasma(n=5) 79-95% 95-103% 78-99% 89-99%
heparin plasma(n=5) 89-103% 89-96% 78-93% 92-104%

Stability of the CLIA Kit for Secondary Lymphoid Tissue Chemokine (SLC)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Secondary Lymphoid Tissue Chemokine (SLC)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Secondary Lymphoid Tissue Chemokine (SLC)

The microplate provided in this kit has been pre-coated with an antibody specific to Secondary Lymphoid Tissue Chemokine (SLC). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Secondary Lymphoid Tissue Chemokine (SLC). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Secondary Lymphoid Tissue Chemokine (SLC) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
APB575Hu01 Active Secondary Lymphoid Tissue Chemokine (SLC) Cell culture; Activity Assays.
RPB575Hu01 Recombinant Secondary Lymphoid Tissue Chemokine (SLC) Positive Control; Immunogen; SDS-PAGE; WB.
PAB575Hu01 Polyclonal Antibody to Secondary Lymphoid Tissue Chemokine (SLC) WB; IHC; ICC; IP.
LAB575Hu71 Biotin-Linked Polyclonal Antibody to Secondary Lymphoid Tissue Chemokine (SLC) WB; IHC; ICC.
MAB575Hu22 Monoclonal Antibody to Secondary Lymphoid Tissue Chemokine (SLC) WB; IHC; ICC; IP.
SEB575Hu ELISA Kit for Secondary Lymphoid Tissue Chemokine (SLC) Enzyme-linked immunosorbent assay for Antigen Detection.
SCB575Hu CLIA Kit for Secondary Lymphoid Tissue Chemokine (SLC) Chemiluminescent immunoassay for Antigen Detection.
LMB575Hu Multiplex Assay Kit for Secondary Lymphoid Tissue Chemokine (SLC) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK