CLIA Kit for Monocyte Chemotactic Protein 1 (MCP1)

CCL2; GDCF2; HC11; HSMCR30; MCAF; MCP1; SCYA2; SMC-CF; Chemokine C-C-Motif Ligand 2; Monocyte Chemotactic And Activating Factor; Monocyte Secretory Protein JE

  • CLIA Kit for Monocyte Chemotactic Protein 1 (MCP1) Packages (Simulation)
  • CLIA Kit for Monocyte Chemotactic Protein 1 (MCP1) Packages (Simulation)
  • CLIA Kit for Monocyte Chemotactic Protein 1 (MCP1) Results demonstration
  • SCA087Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Monocyte Chemotactic Protein 1 (MCP1)

This assay has high sensitivity and excellent specificity for detection of Monocyte Chemotactic Protein 1 (MCP1).
No significant cross-reactivity or interference between Monocyte Chemotactic Protein 1 (MCP1) and analogues was observed.

Recovery of the CLIA Kit for Monocyte Chemotactic Protein 1 (MCP1)

Matrices listed below were spiked with certain level of recombinant Monocyte Chemotactic Protein 1 (MCP1) and the recovery rates were calculated by comparing the measured value to the expected amount of Monocyte Chemotactic Protein 1 (MCP1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-88 81
EDTA plasma(n=5) 85-104 94
heparin plasma(n=5) 83-94 88

Precision of the CLIA Kit for Monocyte Chemotactic Protein 1 (MCP1)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Monocyte Chemotactic Protein 1 (MCP1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Monocyte Chemotactic Protein 1 (MCP1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Monocyte Chemotactic Protein 1 (MCP1)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Monocyte Chemotactic Protein 1 (MCP1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 98-105% 90-102% 82-102%
EDTA plasma(n=5) 79-102% 97-105% 80-101% 93-104%
heparin plasma(n=5) 94-101% 79-95% 90-97% 83-94%

Stability of the CLIA Kit for Monocyte Chemotactic Protein 1 (MCP1)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Monocyte Chemotactic Protein 1 (MCP1)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Monocyte Chemotactic Protein 1 (MCP1)

The microplate provided in this kit has been pre-coated with an antibody specific to Monocyte Chemotactic Protein 1 (MCP1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Monocyte Chemotactic Protein 1 (MCP1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Monocyte Chemotactic Protein 1 (MCP1) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
APA087Hu01 Active Monocyte Chemotactic Protein 1 (MCP1) Cell culture; Activity Assays.
RPA087Hu01 Recombinant Monocyte Chemotactic Protein 1 (MCP1) Positive Control; Immunogen; SDS-PAGE; WB.
PAA087Hu01 Polyclonal Antibody to Monocyte Chemotactic Protein 1 (MCP1) WB; IHC; ICC; IP.
LAA087Hu71 Biotin-Linked Polyclonal Antibody to Monocyte Chemotactic Protein 1 (MCP1) WB; IHC; ICC.
LAA087Hu81 FITC-Linked Polyclonal Antibody to Monocyte Chemotactic Protein 1 (MCP1) WB; IHC; ICC; IF.
MAA087Hu22 Monoclonal Antibody to Monocyte Chemotactic Protein 1 (MCP1) WB; IHC; ICC; IP.
MAA087Hu24 Monoclonal Antibody to Monocyte Chemotactic Protein 1 (MCP1) WB; IHC; ICC; IP.
MAA087Hu21 Monoclonal Antibody to Monocyte Chemotactic Protein 1 (MCP1) WB; IHC; ICC; IP.
LAA087Hu74 Biotin-Linked Monoclonal Antibody to Monocyte Chemotactic Protein 1 (MCP1) WB; IHC; ICC.
MEA087Hu Mini Samples ELISA Kit for Monocyte Chemotactic Protein 1 (MCP1) Enzyme-linked immunosorbent assay for Antigen Detection.
SEA087Hu ELISA Kit for Monocyte Chemotactic Protein 1 (MCP1) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA087Hu CLIA Kit for Monocyte Chemotactic Protein 1 (MCP1) Chemiluminescent immunoassay for Antigen Detection.
LMA087Hu Multiplex Assay Kit for Monocyte Chemotactic Protein 1 (MCP1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
PSA087Hu01 Antibody Pair for Monocyte Chemotactic Protein 1 (MCP1) ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays.
KSA087Hu01 ELISA Kit DIY Materials for Monocyte Chemotactic Protein 1 (MCP1) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK