CLIA Kit for Macrophage Derived Chemokine (MDC)

CCL22; ABCD1; DC/B-CK; SCYA22; STCP1; Chemokine C-C-Motif Ligand 22; Small Inducible Cytokine Subfamily A(Cys-Cys)Member 22; Stimulated T-Cell Chemotactic Protein 1

  • CLIA Kit for Macrophage Derived Chemokine (MDC) Packages (Simulation)
  • CLIA Kit for Macrophage Derived Chemokine (MDC) Packages (Simulation)
  • CLIA Kit for Macrophage Derived Chemokine (MDC) Results demonstration
  • SCA091Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Macrophage Derived Chemokine (MDC)

This assay has high sensitivity and excellent specificity for detection of Macrophage Derived Chemokine (MDC).
No significant cross-reactivity or interference between Macrophage Derived Chemokine (MDC) and analogues was observed.

Recovery of the CLIA Kit for Macrophage Derived Chemokine (MDC)

Matrices listed below were spiked with certain level of recombinant Macrophage Derived Chemokine (MDC) and the recovery rates were calculated by comparing the measured value to the expected amount of Macrophage Derived Chemokine (MDC) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 82-101 92
EDTA plasma(n=5) 97-105 101
heparin plasma(n=5) 82-96 91

Precision of the CLIA Kit for Macrophage Derived Chemokine (MDC)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Macrophage Derived Chemokine (MDC) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Macrophage Derived Chemokine (MDC) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Macrophage Derived Chemokine (MDC)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Macrophage Derived Chemokine (MDC) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-105% 94-103% 81-104% 91-99%
EDTA plasma(n=5) 91-98% 78-102% 95-103% 80-97%
heparin plasma(n=5) 78-95% 96-103% 78-103% 90-99%

Stability of the CLIA Kit for Macrophage Derived Chemokine (MDC)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Macrophage Derived Chemokine (MDC)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Macrophage Derived Chemokine (MDC)

The microplate provided in this kit has been pre-coated with an antibody specific to Macrophage Derived Chemokine (MDC). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Macrophage Derived Chemokine (MDC). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Macrophage Derived Chemokine (MDC) level in the sample or standard.;

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPA091Mu01 Recombinant Macrophage Derived Chemokine (MDC) Positive Control; Immunogen; SDS-PAGE; WB.
RPA091Mu02 Recombinant Macrophage Derived Chemokine (MDC) Positive Control; Immunogen; SDS-PAGE; WB.
PAA091Mu01 Polyclonal Antibody to Macrophage Derived Chemokine (MDC) WB; IHC; ICC; IP.
PAA091Mu02 Polyclonal Antibody to Macrophage Derived Chemokine (MDC) WB; IHC; ICC; IP.
MEA091Mu Mini Samples ELISA Kit for Macrophage Derived Chemokine (MDC) Enzyme-linked immunosorbent assay for Antigen Detection.
SEA091Mu ELISA Kit for Macrophage Derived Chemokine (MDC) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA091Mu CLIA Kit for Macrophage Derived Chemokine (MDC) Chemiluminescent immunoassay for Antigen Detection.
LMA091Mu Multiplex Assay Kit for Macrophage Derived Chemokine (MDC) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA091Mu01 ELISA Kit DIY Materials for Macrophage Derived Chemokine (MDC) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK