CLIA Kit for Interleukin 17 (IL17)

IL17A; CTLA8; IL-17A; Cytotoxic T-Lymphocyte-Associated Protein 8

  • CLIA Kit for Interleukin 17 (IL17) Packages (Simulation)
  • CLIA Kit for Interleukin 17 (IL17) Packages (Simulation)
  • CLIA Kit for Interleukin 17 (IL17) Results demonstration
  • SCA063Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Interleukin 17 (IL17)

This assay has high sensitivity and excellent specificity for detection of Interleukin 17 (IL17).
No significant cross-reactivity or interference between Interleukin 17 (IL17) and analogues was observed.

Recovery of the CLIA Kit for Interleukin 17 (IL17)

Matrices listed below were spiked with certain level of recombinant Interleukin 17 (IL17) and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 17 (IL17) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-98 95
EDTA plasma(n=5) 85-97 93
heparin plasma(n=5) 82-105 98

Precision of the CLIA Kit for Interleukin 17 (IL17)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 17 (IL17) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 17 (IL17) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Interleukin 17 (IL17)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 17 (IL17) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-102% 78-95% 89-98% 91-98%
EDTA plasma(n=5) 89-102% 78-95% 85-102% 79-89%
heparin plasma(n=5) 90-101% 95-104% 92-99% 91-104%

Stability of the CLIA Kit for Interleukin 17 (IL17)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Interleukin 17 (IL17)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Interleukin 17 (IL17)

The microplate provided in this kit has been pre-coated with an antibody specific to Interleukin 17 (IL17). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interleukin 17 (IL17). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Interleukin 17 (IL17) level in the sample or standard.;

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
APA063Mu61 Active Interleukin 17 (IL17) Cell culture; Activity Assays.
RPA063Mu02 Recombinant Interleukin 17 (IL17) Positive Control; Immunogen; SDS-PAGE; WB.
RPA063Mu01 Recombinant Interleukin 17 (IL17) Positive Control; Immunogen; SDS-PAGE; WB.
PAA063Mu01 Polyclonal Antibody to Interleukin 17 (IL17) WB; IHC; ICC; IP.
PAA063Mu02 Polyclonal Antibody to Interleukin 17 (IL17) WB; IHC; ICC; IP.
MAA063Mu22 Monoclonal Antibody to Interleukin 17 (IL17) WB; IHC; ICC; IP.
SEA063Mu ELISA Kit for Interleukin 17 (IL17) Enzyme-linked immunosorbent assay for Antigen Detection.
MEA063Mu Mini Samples ELISA Kit for Interleukin 17 (IL17) Enzyme-linked immunosorbent assay for Antigen Detection.
HEA063Mu High Sensitive ELISA Kit for Interleukin 17 (IL17) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA063Mu CLIA Kit for Interleukin 17 (IL17) Chemiluminescent immunoassay for Antigen Detection.
LMA063Mu Multiplex Assay Kit for Interleukin 17 (IL17) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK