CLIA Kit for Fibroblast Growth Factor Binding Protein 3 (FGFBP3)

C10orf13

  • CLIA Kit for Fibroblast Growth Factor Binding Protein 3 (FGFBP3) Packages (Simulation)
  • CLIA Kit for Fibroblast Growth Factor Binding Protein 3 (FGFBP3) Packages (Simulation)
  • CLIA Kit for Fibroblast Growth Factor Binding Protein 3 (FGFBP3) Results demonstration
  • SCR098Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Fibroblast Growth Factor Binding Protein 3 (FGFBP3)

This assay has high sensitivity and excellent specificity for detection of Fibroblast Growth Factor Binding Protein 3 (FGFBP3).
No significant cross-reactivity or interference between Fibroblast Growth Factor Binding Protein 3 (FGFBP3) and analogues was observed.

Precision of the CLIA Kit for Fibroblast Growth Factor Binding Protein 3 (FGFBP3)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fibroblast Growth Factor Binding Protein 3 (FGFBP3) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fibroblast Growth Factor Binding Protein 3 (FGFBP3) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability of the CLIA Kit for Fibroblast Growth Factor Binding Protein 3 (FGFBP3)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Fibroblast Growth Factor Binding Protein 3 (FGFBP3)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Fibroblast Growth Factor Binding Protein 3 (FGFBP3)

The microplate provided in this kit has been pre-coated with an antibody specific to Fibroblast Growth Factor Binding Protein 3 (FGFBP3). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Fibroblast Growth Factor Binding Protein 3 (FGFBP3). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Fibroblast Growth Factor Binding Protein 3 (FGFBP3) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
SCR098Hu CLIA Kit for Fibroblast Growth Factor Binding Protein 3 (FGFBP3) Chemiluminescent immunoassay for Antigen Detection.
GUESTBOOK