CLIA Kit for Factor Related Apoptosis (FAS)

CD95; ALPS1A; ALPS1-A; APO1; APT1; FAS1; FASTM; TNFRSF6; Fas Receptor; TNF Receptor Superfamily Member 6; Tumor Necrosis Factor Receptor Superfamily Member 6

  • CLIA Kit for Factor Related Apoptosis (FAS) Packages (Simulation)
  • CLIA Kit for Factor Related Apoptosis (FAS) Packages (Simulation)
  • CLIA Kit for Factor Related Apoptosis (FAS) Results demonstration
  • SCA030Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Factor Related Apoptosis (FAS)

This assay has high sensitivity and excellent specificity for detection of Factor Related Apoptosis (FAS).
No significant cross-reactivity or interference between Factor Related Apoptosis (FAS) and analogues was observed.

Recovery of the CLIA Kit for Factor Related Apoptosis (FAS)

Matrices listed below were spiked with certain level of recombinant Factor Related Apoptosis (FAS) and the recovery rates were calculated by comparing the measured value to the expected amount of Factor Related Apoptosis (FAS) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 98-105 101
EDTA plasma(n=5) 80-92 86
heparin plasma(n=5) 81-97 87

Precision of the CLIA Kit for Factor Related Apoptosis (FAS)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Factor Related Apoptosis (FAS) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Factor Related Apoptosis (FAS) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Factor Related Apoptosis (FAS)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Factor Related Apoptosis (FAS) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-101% 88-95% 91-103% 83-101%
EDTA plasma(n=5) 84-98% 79-94% 86-103% 80-99%
heparin plasma(n=5) 98-105% 84-98% 81-94% 85-92%

Stability of the CLIA Kit for Factor Related Apoptosis (FAS)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Factor Related Apoptosis (FAS)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Factor Related Apoptosis (FAS)

The microplate provided in this kit has been pre-coated with an antibody specific to Factor Related Apoptosis (FAS). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Factor Related Apoptosis (FAS). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Factor Related Apoptosis (FAS) level in the sample or standard.;

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
EPA030Mu61 Eukaryotic Factor Related Apoptosis (FAS) Positive Control; Immunogen; SDS-PAGE; WB.
RPA030Mu01 Recombinant Factor Related Apoptosis (FAS) Positive Control; Immunogen; SDS-PAGE; WB.
RPA030Mu02 Recombinant Factor Related Apoptosis (FAS) Positive Control; Immunogen; SDS-PAGE; WB.
PAA030Mu02 Polyclonal Antibody to Factor Related Apoptosis (FAS) WB; IHC; ICC; IP.
PAA030Mu01 Polyclonal Antibody to Factor Related Apoptosis (FAS) WB; IHC; ICC; IP.
LAA030Mu71 Biotin-Linked Polyclonal Antibody to Factor Related Apoptosis (FAS) WB; IHC; ICC.
SEA030Mu ELISA Kit for Factor Related Apoptosis (FAS) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA030Mu CLIA Kit for Factor Related Apoptosis (FAS) Chemiluminescent immunoassay for Antigen Detection.
LMA030Mu Multiplex Assay Kit for Factor Related Apoptosis (FAS) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA030Mu01 ELISA Kit DIY Materials for Factor Related Apoptosis (FAS) Main materials for "Do It(ELISA Kit) Yourself"
GUESTBOOK