CLIA Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78)

CXCL5; SCYB5; Chemokine C-X-C-Motif Ligand 5; Small Inducible Cytokine Subfamily B(Cys-X-Cys),Member 5; Neutrophil-activating peptide ENA-78

  • CLIA Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78) Packages (Simulation)
  • CLIA Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78) Packages (Simulation)
  • CLIA Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78) Results demonstration
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78)

This assay has high sensitivity and excellent specificity for detection of Epithelial Neutrophil Activating Peptide 78 (ENA78).
No significant cross-reactivity or interference between Epithelial Neutrophil Activating Peptide 78 (ENA78) and analogues was observed.

Recovery of the CLIA Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78)

Matrices listed below were spiked with certain level of recombinant Epithelial Neutrophil Activating Peptide 78 (ENA78) and the recovery rates were calculated by comparing the measured value to the expected amount of Epithelial Neutrophil Activating Peptide 78 (ENA78) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 82-96 92
EDTA plasma(n=5) 78-103 87
heparin plasma(n=5) 81-98 86

Precision of the CLIA Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Epithelial Neutrophil Activating Peptide 78 (ENA78) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Epithelial Neutrophil Activating Peptide 78 (ENA78) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Epithelial Neutrophil Activating Peptide 78 (ENA78) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 85-95% 84-93% 81-95% 78-105%
EDTA plasma(n=5) 83-98% 92-101% 91-98% 97-105%
heparin plasma(n=5) 91-103% 95-103% 91-104% 87-97%

Stability of the CLIA Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78)

The microplate provided in this kit has been pre-coated with an antibody specific to Epithelial Neutrophil Activating Peptide 78 (ENA78). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Epithelial Neutrophil Activating Peptide 78 (ENA78). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Epithelial Neutrophil Activating Peptide 78 (ENA78) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
APA860Hu01 Active Epithelial Neutrophil Activating Peptide 78 (ENA78) Cell culture; Activity Assays.
RPA860Hu02 Recombinant Epithelial Neutrophil Activating Peptide 78 (ENA78) Positive Control; Immunogen; SDS-PAGE; WB.
EPA860Hu61 Eukaryotic Epithelial Neutrophil Activating Peptide 78 (ENA78) Positive Control; Immunogen; SDS-PAGE; WB.
RPA860Hu03 Recombinant Epithelial Neutrophil Activating Peptide 78 (ENA78) Positive Control; Immunogen; SDS-PAGE; WB.
APA860Hu61 Active Epithelial Neutrophil Activating Peptide 78 (ENA78) Cell culture; Activity Assays.
RPA860Hu01 Recombinant Epithelial Neutrophil Activating Peptide 78 (ENA78) Positive Control; Immunogen; SDS-PAGE; WB.
APA860Hu02 Active Epithelial Neutrophil Activating Peptide 78 (ENA78) Cell culture; Activity Assays.
APA860Hu03 Active Epithelial Neutrophil Activating Peptide 78 (ENA78) Cell culture; Activity Assays.
PAA860Hu02 Polyclonal Antibody to Epithelial Neutrophil Activating Peptide 78 (ENA78) WB; IHC; ICC; IP.
PAA860Hu03 Polyclonal Antibody to Epithelial Neutrophil Activating Peptide 78 (ENA78) WB; IHC; ICC; IP.
PAA860Hu01 Polyclonal Antibody to Epithelial Neutrophil Activating Peptide 78 (ENA78) WB; IHC; ICC; IP.
LAA860Hu81 FITC-Linked Polyclonal Antibody to Epithelial Neutrophil Activating Peptide 78 (ENA78) WB; IHC; ICC; IF.
LAA860Hu71 Biotin-Linked Polyclonal Antibody to Epithelial Neutrophil Activating Peptide 78 (ENA78) WB; IHC; ICC.
MAA860Hu22 Monoclonal Antibody to Epithelial Neutrophil Activating Peptide 78 (ENA78) WB; IHC; ICC; IP.
SEA860Hu ELISA Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78) Enzyme-linked immunosorbent assay for Antigen Detection.
AEA860Hu ELISA Kit for Anti-Epithelial Neutrophil Activating Peptide 78 Antibody (Anti-ENA78) Enzyme-linked immunosorbent assay for Antibody Detection.
SCA860Hu CLIA Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78) Chemiluminescent immunoassay for Antigen Detection.
LMA860Hu Multiplex Assay Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA860Hu01 ELISA Kit DIY Materials for Epithelial Neutrophil Activating Peptide 78 (ENA78) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK