CLIA Kit for Beta-Endorphin (bEP)

b-EP

  • CLIA Kit for Beta-Endorphin (bEP) Packages (Simulation)
  • CLIA Kit for Beta-Endorphin (bEP) Packages (Simulation)
  • CLIA Kit for Beta-Endorphin (bEP) Results demonstration
  • CCA806Ra.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Beta-Endorphin (bEP)

This assay has high sensitivity and excellent specificity for detection of Beta-Endorphin (bEP).
No significant cross-reactivity or interference between Beta-Endorphin (bEP) and analogues was observed.

Recovery of the CLIA Kit for Beta-Endorphin (bEP)

Matrices listed below were spiked with certain level of recombinant Beta-Endorphin (bEP) and the recovery rates were calculated by comparing the measured value to the expected amount of Beta-Endorphin (bEP) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-95 90
EDTA plasma(n=5) 80-99 89
heparin plasma(n=5) 84-97 91

Precision of the CLIA Kit for Beta-Endorphin (bEP)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Beta-Endorphin (bEP) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Beta-Endorphin (bEP) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Beta-Endorphin (bEP)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Beta-Endorphin (bEP) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 90-101% 97-105% 81-105% 97-104%
EDTA plasma(n=5) 94-101% 97-104% 78-94% 83-90%
heparin plasma(n=5) 80-103% 95-103% 94-102% 80-104%

Stability of the CLIA Kit for Beta-Endorphin (bEP)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Beta-Endorphin (bEP)

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
7. Read RLU value immediately.

Test principle of the CLIA Kit for Beta-Endorphin (bEP)

The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Beta-Endorphin (bEP). A competitive inhibition reaction is launched between biotin labeled Beta-Endorphin (bEP) and unlabeled Beta-Endorphin (bEP) (Standards or samples) with the pre-coated antibody specific to Beta-Endorphin (bEP). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Beta-Endorphin (bEP) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Beta-Endorphin (bEP) level in the sample or standard.

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
CPA806Ra21 OVA Conjugated Beta-Endorphin (bEP) Immunogen; SDS-PAGE; WB.
PAA806Ra01 Polyclonal Antibody to Beta-Endorphin (bEP) IHC; ICC; IP.
CEA806Ra ELISA Kit for Beta-Endorphin (bEP) Enzyme-linked immunosorbent assay for Antigen Detection.
CCA806Ra CLIA Kit for Beta-Endorphin (bEP) Chemiluminescent immunoassay for Antigen Detection.
LMA806Ra Multiplex Assay Kit for Beta-Endorphin (bEP) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA806Ra11 ELISA Kit DIY Materials for Beta-Endorphin (bEP) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK