CLIA Kit for B-Cell Leukemia/Lymphoma 2 (Bcl2)

B-Cell CLL/Lymphoma 2

  • CLIA Kit for B-Cell Leukemia/Lymphoma 2 (Bcl2) Packages (Simulation)
  • CLIA Kit for B-Cell Leukemia/Lymphoma 2 (Bcl2) Packages (Simulation)
  • CLIA Kit for B-Cell Leukemia/Lymphoma 2 (Bcl2) Results demonstration
  • SCA778Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for B-Cell Leukemia/Lymphoma 2 (Bcl2)

This assay has high sensitivity and excellent specificity for detection of B-Cell Leukemia/Lymphoma 2 (Bcl2).
No significant cross-reactivity or interference between B-Cell Leukemia/Lymphoma 2 (Bcl2) and analogues was observed.

Recovery of the CLIA Kit for B-Cell Leukemia/Lymphoma 2 (Bcl2)

Matrices listed below were spiked with certain level of recombinant B-Cell Leukemia/Lymphoma 2 (Bcl2) and the recovery rates were calculated by comparing the measured value to the expected amount of B-Cell Leukemia/Lymphoma 2 (Bcl2) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-102 93
EDTA plasma(n=5) 78-94 83
heparin plasma(n=5) 84-91 88

Precision of the CLIA Kit for B-Cell Leukemia/Lymphoma 2 (Bcl2)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level B-Cell Leukemia/Lymphoma 2 (Bcl2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level B-Cell Leukemia/Lymphoma 2 (Bcl2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for B-Cell Leukemia/Lymphoma 2 (Bcl2)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of B-Cell Leukemia/Lymphoma 2 (Bcl2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-101% 78-91% 99-105% 78-95%
EDTA plasma(n=5) 82-94% 81-101% 92-101% 88-96%
heparin plasma(n=5) 88-95% 90-103% 81-95% 80-91%

Stability of the CLIA Kit for B-Cell Leukemia/Lymphoma 2 (Bcl2)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for B-Cell Leukemia/Lymphoma 2 (Bcl2)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for B-Cell Leukemia/Lymphoma 2 (Bcl2)

The microplate provided in this kit has been pre-coated with an antibody specific to B-Cell Leukemia/Lymphoma 2 (Bcl2). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to B-Cell Leukemia/Lymphoma 2 (Bcl2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the B-Cell Leukemia/Lymphoma 2 (Bcl2) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPA778Hu01 Recombinant B-Cell Leukemia/Lymphoma 2 (Bcl2) Positive Control; Immunogen; SDS-PAGE; WB.
PAA778Hu01 Polyclonal Antibody to B-Cell Leukemia/Lymphoma 2 (Bcl2) WB,IHC,ICC/IF
LAA778Hu81 FITC-Linked Polyclonal Antibody to B-Cell Leukemia/Lymphoma 2 (Bcl2) WB; IHC; ICC; IF.
LAA778Hu71 Biotin-Linked Polyclonal Antibody to B-Cell Leukemia/Lymphoma 2 (Bcl2) WB; IHC; ICC.
MAA778Hu22 Monoclonal Antibody to B-Cell Leukemia/Lymphoma 2 (Bcl2) WB; IHC; ICC; IP.
MAA778Hu21 Monoclonal Antibody to B-Cell Leukemia/Lymphoma 2 (Bcl2) WB; IHC; ICC; IP.
MAA778Hu23 Monoclonal Antibody to B-Cell Leukemia/Lymphoma 2 (Bcl2) WB; IHC; ICC; IP.
MAA778Hu24 Monoclonal Antibody to B-Cell Leukemia/Lymphoma 2 (Bcl2) WB; IHC; ICC; IP.
MAA778Hu25 Monoclonal Antibody to B-Cell Leukemia/Lymphoma 2 (Bcl2) WB; IHC; ICC; IP.
SEA778Hu ELISA Kit for B-Cell Leukemia/Lymphoma 2 (Bcl2) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA778Hu CLIA Kit for B-Cell Leukemia/Lymphoma 2 (Bcl2) Chemiluminescent immunoassay for Antigen Detection.
LMA778Hu Multiplex Assay Kit for B-Cell Leukemia/Lymphoma 2 (Bcl2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.