CLIA Kit for Aryl Hydrocarbon Receptor (AhR)

BHLHE76; Class E basic helix-loop-helix protein 76

  • CLIA Kit for Aryl Hydrocarbon Receptor (AhR) Packages (Simulation)
  • CLIA Kit for Aryl Hydrocarbon Receptor (AhR) Packages (Simulation)
  • CLIA Kit for Aryl Hydrocarbon Receptor (AhR) Results demonstration
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Aryl Hydrocarbon Receptor (AhR)

This assay has high sensitivity and excellent specificity for detection of Aryl Hydrocarbon Receptor (AhR).
No significant cross-reactivity or interference between Aryl Hydrocarbon Receptor (AhR) and analogues was observed.

Precision of the CLIA Kit for Aryl Hydrocarbon Receptor (AhR)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Aryl Hydrocarbon Receptor (AhR) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Aryl Hydrocarbon Receptor (AhR) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability of the CLIA Kit for Aryl Hydrocarbon Receptor (AhR)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Aryl Hydrocarbon Receptor (AhR)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Aryl Hydrocarbon Receptor (AhR)

The microplate provided in this kit has been pre-coated with an antibody specific to Aryl Hydrocarbon Receptor (AhR). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Aryl Hydrocarbon Receptor (AhR). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Aryl Hydrocarbon Receptor (AhR) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
APB354Hu01 Active Aryl Hydrocarbon Receptor (AhR) Cell culture; Activity Assays.
RPB354Hu01 Recombinant Aryl Hydrocarbon Receptor (AhR) Positive Control; Immunogen; SDS-PAGE; WB.
PAB354Hu01 Polyclonal Antibody to Aryl Hydrocarbon Receptor (AhR) WB,IHC
MAB354Hu22 Monoclonal Antibody to Aryl Hydrocarbon Receptor (AhR) WB; IHC; ICC; IP.
MAB354Hu21 Monoclonal Antibody to Aryl Hydrocarbon Receptor (AhR) WB; IHC; ICC; IP.
SEB354Hu ELISA Kit for Aryl Hydrocarbon Receptor (AhR) Enzyme-linked immunosorbent assay for Antigen Detection.
SCB354Hu CLIA Kit for Aryl Hydrocarbon Receptor (AhR) Chemiluminescent immunoassay for Antigen Detection.
LMB354Hu Multiplex Assay Kit for Aryl Hydrocarbon Receptor (AhR) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK